CONICA: the high-resolution near-infrared camera for the ESO VLT
The DOI matches its Crossref record.
Abstract
A high resolution near IR camera (CONICA) for the firs VLT unit is under development, which will provide diffraction limited spatial resolution being combined with the adaptive optics system NAOS. CONICA serves as a multi-mode instrument for the wavelength region between 1.0 and 5.0 micrometers , offering broad band, narrow band or Fabry Perot direct imaging capabilities, polarimetric modes using Wollaston prism or wire grid analyzers and long slit spectroscopy up to a spectral resolution of about 1000 per two pixel. We presented a first concept of CONICA in 1995. In the mean time, large parts of the instrument have been manufactured, the cryostat and the adapter have been finished and first cryogenic test have been performed. This paper describes the actual design and status of development of CONICA focusing on those aspects which have not been described in detail before or the design of which have been changed in the mean time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
MONITORING STELLAR ORBITS AROUND THE MASSIVE BLACK HOLE IN THE GALACTIC CENTER
Gillessen, S., Eisenhauer, F., Trippe, S., Alexander, T., Genzel, R., Martins, F., & Ott, T. (2009) · The Astrophysical Journal · doi:10.1088/0004-637x/692/2/1075 · Cited by 1,779
A star in a 15.2-year orbit around the supermassive black hole at the centre of the Milky Way
Schödel, R., Ott, T., Genzel, R., Hofmann, R., Lehnert, M., Eckart, A., Mouawad, N., Alexander, T., Reid, M. J., Lenzen, R., et al. (2002) · Nature · doi:10.1038/nature01121 · Cited by 1,166
Self-citationGRAVITY Collaboration, Abuter, R., Amorim, A., Anugu, N., Bauböck, M., Benisty, M., Berger, J. P., Blind, N., Bonnet, H., Brandner, W., et al. (2018) · Astronomy & Astrophysics · doi:10.1051/0004-6361/201833718 · Cited by 946
“…camera SHARP at the NTT (1992-2002: Hofmann et al. 1993), but most of our imaging comes from the AO-assisted NIR imager NACO at the VLT (2002-2018: Lenzen et al. 1998; Rousset et al. 1998) and the interferometric astrometryimager GRAVITY with all four Unit Telescopes (UTs) of the VLT…”
MethodSelf-citationNear-infrared flares from accreting gas around the supermassive black hole at the Galactic Centre
Genzel, R., Schödel, R., Ott, T., Eckart, A., Alexander, T., Lacombe, F., Rouan, D., & Aschenbach, B. (2003) · Nature · doi:10.1038/nature02065 · Cited by 688
SINFONI in the Galactic Center: Young Stars and Infrared Flares in the Central Light‐Month
Eisenhauer, F., Genzel, R., Alexander, T., Abuter, R., Paumard, T., Ott, T., Gilbert, A., Gillessen, S., Horrobin, M., Trippe, S., et al. (2005) · The Astrophysical Journal · doi:10.1086/430667 · Cited by 662
Metadata
- Authors
- Lenzen, R., Hofmann, R., Bizenberger, P., & Tusche, A.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 1998-08-21
- Volume
- 3354
- Pages
- 606
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2076344505
- Cited by
- 140
- References
- 0
- FWCI
- 0.72
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CONICA: the high-resolution near-infrared camera for the ESO VLT. https://app.cochat.ai/papers/10.1117/12.317287
- The paper
- Lenzen, R., Hofmann, R., Bizenberger, P., & Tusche, A. (1998). CONICA: the high-resolution near-infrared camera for the ESO VLT. SPIE Proceedings. https://doi.org/10.1117/12.317287
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.