The DOI matches its Crossref record.
Dielectric elastomer artificial muscle actuators: toward biomimetic motion:
Abstract
To achieve desirable biomimetic motion, actuators must be able to reproduce the important features of natural muscle such as power, stress, strain, speed of response, efficiency, and controllability. It is a mistake, however, to consider muscle as only an energy output device. Muscle is multifunctional. In locomotion, muscle often acts as an energy absorber, variable-stiffness suspension element, or position sensor, for example. Electroactive polymer technologies based on the electric-field-induced deformation of polymer dielectrics with compliant electrodes are particularly promising because they have demonstrated high strains and energy densities. Testing with experimental biological techniques and apparatus has confirmed that these dielectric elastomer artificial muscles can indeed reproduce several of the important characteristics of natural muscle. Several different artificial muscle actuator configurations have been tested, including flat actuators and tubular rolls. Rolls have been shown to act as structural elements and to incorporate position sensing. Biomimetic robot applications have been explored that exploit the muscle-like capabilities of the dielectric elastomer actuators, including serpentine manipulators, insect-like flapping-wing mechanisms, and insect-like walking robots.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Soft Robotics: Biological Inspiration, State of the Art, and Future Research
Trivedi, D., Rahn, C. D., Kier, W. M., & Walker, I. D. (2008) · Applied Bionics and Biomechanics · doi:10.1080/11762320802557865 · Cited by 1,708
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Artificial Muscles: Mechanisms, Applications, and Challenges
Mirvakili, S. M., & Hunter, I. W. (2018) · Advanced Materials · doi:10.1002/adma.201704407 · Cited by 1,077
Artificial Muscle Technology: Physical Principles and Naval Prospects
Madden, J. D. W., Vandesteeg, N. A., Anquetil, P. A., Madden, P. G. A., Takshi, A., Pytel, R. Z., Lafontaine, S. R., Wieringa, P. A., & Hunter, I. W. (2004) · IEEE Journal of Oceanic Engineering · doi:10.1109/joe.2004.833135 · Cited by 1,035
Mirfakhrai, T., Madden, J. D. W., & Baughman, R. H. (2007) · Materials Today · doi:10.1016/s1369-7021(07)70048-2 · Cited by 933
Metadata
- Authors
- Pelrine, R., Kornbluh, R. D., Pei, Q., Stanford, S., Oh, S., Eckerle, J., Full, R. J., Rosenthal, M. A., & Meijer, K.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2002-07-10
- Volume
- 4695
- Pages
- 126-137
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2143484511
- Cited by
- 276
- References
- 0
- FWCI
- 1.34
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dielectric elastomer artificial muscle actuators: toward biomimetic motion:. https://app.cochat.ai/papers/10.1117/12.475157
- The paper
- Pelrine, R., Kornbluh, R. D., Pei, Q., Stanford, S., Oh, S., Eckerle, J., Full, R. J., Rosenthal, M. A., & Meijer, K. (2002). Dielectric elastomer artificial muscle actuators: toward biomimetic motion:. SPIE Proceedings. https://doi.org/10.1117/12.475157
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.