Cited by 92Terahertz technology and applicationsOptical Coherence Tomography ApplicationsOptical Imaging and Spectroscopy Techniques

Optical properties of tissue measured using terahertz pulsed imaging

Berry, Elizabeth, Fitzgerald, Anthony J., Zinov'ev, Nickolay N., Walker, Gillian C., Homer-Vanniasinkam, Shervanthi, Sudworth, Caroline D., Miles, Robert E., Chamberlain, J. Martyn +1 more·2003·SPIE Proceedings

Abstract

The first demonstrations of terahertz imaging in biomedicine were made several years ago, but few data are available on the optical properties of human tissue at terahertz frequencies. A catalogue of these properties has been established to estimate variability and determine the practicality of proposed medical applications in terms of penetration depth, image contrast and reflection at boundaries. A pulsed terahertz imaging system with a useful bandwidth 0.5-2.5 THz was used. Local ethical committee approval was obtained. Transmission measurements were made through tissue slices of thickness 0.08 to 1 mm, including tooth enamel and dentine, cortical bone, skin, adipose tissue and striated muscle. The mean and standard deviation for refractive index and linear attenuation coefficient, both broadband and as a function of frequency, were calculated. The measurements were used in simple models of the transmission, reflection and propagation of terahertz radiation in potential medical applications. Refractive indices ranged from 1.5 ± 0.5 for adipose tissue to 3.06 ± 0.09 for tooth enamel. Significant differences (P < 0.05) were found between the broadband refractive indices of a number of tissues. Terahertz radiation is strongly absorbed in tissue so reflection imaging, which has lower penetration requirements than transmission, shows promise for dental or dermatological applications.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/12.479993

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 5

  1. [6]6. International Commission on Non-Ionizing Radiation Protection, "Guidelines on limits of exposure to laser radiation of wavelengths between 180 nm and 1,000 µm", Health Physics , 71, pp. 804-819, 1996.
  2. [8]8. D.H.Auston, K.P.Cheung, J.A.Valdmanis, D.A.Kleinman, "Coherent time-domain far-infrared spectroscopy with femtosecond pulses", Journal of the Optical Society of America A-Optics Image Science and Vision , 1, pp. 12781278, 1984.
  3. [15]15. J.W.Handley, A.J.Fitzgerald, E.Berry, R.D.Boyle, "Approaches to segmentation in medical terahertz pulsed imaging", Proceedings of Medical Image Understanding and Analysis , 2002 , pp. 157-160, 2002.
  4. [19]19. Institute of Electrical and Electronic Engineers, Standard for safety levels with respect to human exposure to radiofrequency electromagnetic fields, 3 kHz to 300 GHz (IEEE C95.1 1999 Edition); Institute of Electrical and Electronic Engineers, New York, 1999.
  5. [23]23. R.M.Woodward, B.Cole, V.P.Wallace, D.D.Arnone, R.Pye, E.H.Linfield et al., "Terahertz pulse imaging of invitro basal cell carcinoma samples", Lasers and Electro-Optics, 2001 CLEO '01 Technical Digest , pp. 329-330, 2001.

Cited by

Sorted by citations

Authors
Berry, E., Fitzgerald, A. J., Zinov'ev, N. N., Walker, G. C., Homer-Vanniasinkam, S., Sudworth, C. D., Miles, R. E., Chamberlain, J. M., & Smith, M. A.
Affiliations
University of Leeds (GB)
Venue
SPIE Proceedings
Publisher
SPIE
Published
2003-06-09
Volume
5030
Pages
459
ISSN
0277-786X (ISSN-L)
OpenAlex
W2054586404
Cited by
92
References
37
Citations by year
2025: 1 · 2023: 6 · 2022: 5 · 2021: 7 · 2020: 4 · 2019: 8 · 2018: 8 · 2017: 5 · 2016: 11 · 2015: 6 · 2013: 10 · 2012: 1
FWCI
3.89
Type
conference paper
Language
en
Open access
closed
Locations
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE (publishedVersion)
  • White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
  • UCL Discovery (University College London) (submittedVersion)
  • SHURA (Sheffield Hallam University Research Archive) (Sheffield Hallam University) (submittedVersion)
Funders
  • European Commission
  • Engineering and Physical Sciences Research Council
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
terahertz imaging, tissue optical properties, refractive index, linear attenuation coefficient, terahertz absorption, dental enamel, dentin, cortical bone, skin, adipose tissue, striated muscle, penetration depth, reflection imaging, dental imaging, skin imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review