Variation and extrema of human interpupillary distance:
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Mean interpupillary distance (IPD) is an important and oft-quoted measure in stereoscopic work. However, there is startlingly little agreement on what it should be. Mean IPD has been quoted in the stereoscopic literature as being anything from 58 mm to 70 mm. It is known to vary with respect to age, gender and race. Furthermore, the stereoscopic industry requires information on not just mean IPD, but also its variance and its extrema, because our products need to be able to cope with all possible users, including those with the smallest and largest IPDs. This paper brings together those statistics on IPD which are available. The key results are that mean adult IPD is around 63 mm, the vast majority of adults have IPDs in the range 50-75 mm, the wider range of 45-80 mm is likely to include (almost) all adults, and the minimum IPD for children (down to five years old) is around 40 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Body space anthropometry, ergonomics and design
(1986) · Applied Ergonomics · doi:10.1016/0003-6870(86)90303-0 · Cited by 273
Measurer's Handbook: U.S. Army Anthropometric Survey, 1987-1988
Clauser, C. E., Tebbetts, I., Bradtmiller, B., McConville, J. T., & Gordon, C. C. (1988) · Defense Technical Information Center (DTIC) · doi:10.21236/ada202721 · Cited by 88
Accommodative-convergence in young infants: Development of a synergistic sensory-motor system.
Aslin, R. Ν., & Jackson, R. W. (1979) · Canadian Journal of Psychology/Revue Canadienne de Psychologie · doi:10.1037/h0081722 · Cited by 55
Ultrasonic fetal ophthalmology
Birnholz, J. C. (1985) · Early Human Development · doi:10.1016/0378-3782(85)90182-3 · Cited by 53
Cited by
Visual Discomfort and Visual Fatigue of Stereoscopic Displays: A Review
Lambooij, M., Fortuin, M., Heynderickx, I., & IJsselsteijn, W. (2009) · Journal of Imaging Science and Technology · doi:10.2352/j.imagingsci.technol.2009.53.3.030201 · Cited by 1,006
The zone of comfort: Predicting visual discomfort with stereo displays
Shibata, T., Kim, J., Hoffman, D. M., & Banks, M. S. (2011) · Journal of Vision · doi:10.1167/11.8.11 · Cited by 596
Quality Assessment of Stereoscopic Images
Benoit, A., Le Callet, P., Campisi, P., & Cousseau, R. (2008) · EURASIP Journal on Image and Video Processing · doi:10.1155/2008/659024 · Cited by 374
A multi-directional backlight for a wide-angle, glasses-free three-dimensional display
Fattal, D., Peng, Z., Tran, T., Vo, S., Fiorentino, M., Brug, J., & Beausoleil, R. G. (2013) · Nature · doi:10.1038/nature11972 · Cited by 341
3D Constrained Local Model for rigid and non-rigid facial tracking
Baltrusaitis, T., Robinson, P., & Morency, L. (2012) · 2012 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2012.6247980 · Cited by 313
Virtual Reality Is Sexist: But It Does Not Have to Be
Stanney, K., Fidopiastis, C., & Foster, L. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.00004 · Cited by 300
Visual discomfort in stereoscopic displays: a review
Lambooij, M. T. M., IJsselsteijn, W. A., & Heynderickx, I. (2007) · SPIE Proceedings · doi:10.1117/12.705527 · Cited by 259
Anderson, R., Gallup, D., Barron, J. T., Kontkanen, J., Snavely, N., Hernández, C., Agarwal, S., & Seitz, S. M. (2016) · ACM Transactions on Graphics · doi:10.1145/2980179.2980257 · Cited by 225
“…and azimuth ✓, the viewing ray directions in vector form are [sin(✓) sin( ), cos( ), cos(✓) sin( )] and the viewing ray origins are ±[r cos(✓), 0, r sin(✓)] where + is for the right eye, is for the left eye, and r is generally half of the average viewer’s interpupillary distance[Dodgson 2004].”
BackgroundAR/VR light engines: perspectives and challenges
Hsiang, E.-L., Yang, Z., Yang, Q., Lai, P.-C., Lin, C.-L., & Wu, S.-T. (2022) · Advances in Optics and Photonics · doi:10.1364/aop.468066 · Cited by 218
Communicating Directionality in Flying Robots
Szafir, D., Mutlu, B., & Fong, T. (2015) · Proceedings of the Tenth Annual ACM/IEEE International Conference on Human-Robot Interaction · doi:10.1145/2696454.2696475 · Cited by 189
“We designed eye sizes, distances between the eyes, and rotation speeds using measurements of human eye size [28], inter-pupillary distances [6], and saccade timings [10], and applied scaling factors to account for size differences between the human head and the LED ring.”
MethodSeuntiens, P., Meesters, L., & Ijsselsteijn, W. (2006) · ACM Transactions on Applied Perception · doi:10.1145/1141897.1141899 · Cited by 169
“…[Computer Graphics]: Three Dimensional Graphics and Realism; I.4.10 [Image Processing and Computer Vision]: Image Representation General Terms: Human factors Additional Key Words and Phrases: Asymmetric/symmetric JPEG coding, depth, eye strain, image quality, sharpness, stereoscopic images 1.”
BackgroundInfluentialThe relationship between individual characteristics and experienced presence
Ling, Y., Nefs, H. T., Brinkman, W.-P., Qu, C., & Heynderickx, I. (2013) · Computers in Human Behavior · doi:10.1016/j.chb.2012.12.010 · Cited by 138
Keane, B. P., Silverstein, S. M., Wang, Y., & Papathomas, T. V. (2013) · Journal of Abnormal Psychology · doi:10.1037/a0032110 · Cited by 106
A High-Level Description and Performance Evaluation of Pupil Invisible
Tonsen, M., Baumann, C. K., & Dierkes, K. (2020) · arXiv · doi:10.48550/arxiv.2009.00508 · Cited by 34
“2 cm and is comparable to similar results reported in the literature [19].”
Result
Metadata
- Authors
- Dodgson, N. A.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2004-05-21
- Volume
- 5291
- Pages
- 36-46
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2085790719
- Cited by
- 396
- References
- 4
- FWCI
- 4.00
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.