The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Visual discomfort in stereoscopic displays: a review
Abstract
Visual discomfort has been the subject of considerable research in relation to stereoscopic and autostereoscopic displays, but remains an ambiguous concept used to denote a variety of subjective symptoms potentially related to different underlying processes. In this paper we clarify the importance of various causes and aspects of visual comfort. Classical causative factors such as excessive binocular parallax and accommodation-convergence conflict appear to be of minor importance when disparity values do not surpass one degree limit of visual angle, which still provides sufficient range to allow for satisfactory depth perception in consumer applications, such as stereoscopic television. Visual discomfort, however, may still occur within this limit and we believe the following factors to be the most pertinent in contributing to this: (1) excessive demand of accommodation-convergence linkage, e.g., by fast motion in depth, viewed at short distances, (2) 3D artefacts resulting from insufficient depth information in the incoming data signal yielding spatial and temporal inconsistencies, and (3) unnatural amounts of blur. In order to adequately characterize and understand visual discomfort, multiple types of measurements, both objective and subjective, are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · Information Visualization · doi:10.1016/b978-0-12-381464-7.00018-1 · Cited by 3,742
Depth-image-based rendering (DIBR), compression, and transmission for a new approach on 3D-TV:
Fehn, C. (2004) · SPIE Proceedings · doi:10.1117/12.524762 · Cited by 1,349
Shade, J., Gortler, S., He, L.-W., & Szeliski, R. (1998) · Proceedings of the 25th annual conference on Computer graphics and interactive techniques - SIGGRAPH '98 · doi:10.1145/280814.280882 · Cited by 1,115
Perceiving Layout and Knowing Distances
Cutting, J. E., & Vishton, P. M. (1995) · Perception of Space and Motion · doi:10.1016/b978-012240530-3/50005-5 · Cited by 1,029
Computer Vision Syndrome: A Review
Blehm, C., Vishnu, S., Khattak, A., Mitra, S., & Yee, R. W. (2005) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2005.02.008 · Cited by 860
Goodwin, C. (1995) · Social Studies of Science · doi:10.1177/030631295025002002 · Cited by 610
Mark, W. R., McMillan, L., & Bishop, G. (1997) · Proceedings of the 1997 symposium on Interactive 3D graphics - SI3D '97 · doi:10.1145/253284.253292 · Cited by 483
Natural problems for stereoscopic depth perception in virtual environments
Wann, J. P., Rushton, S., & Mon-Williams, M. (1995) · Vision Research · doi:10.1016/0042-6989(95)00018-u · Cited by 405
Variation and extrema of human interpupillary distance:
Dodgson, N. A. (2004) · SPIE Proceedings · doi:10.1117/12.529999 · Cited by 396
Image distortions in stereoscopic video systems:
Woods, A. J., Docherty, T., & Koch, R. (1993) · SPIE Proceedings · doi:10.1117/12.157041 · Cited by 371
Cited by
Full-reference quality assessment of stereopairs accounting for rivalry
Chen, M.-J., Su, C.-C., Kwon, D.-K., Cormack, L. K., & Bovik, A. C. (2013) · Signal Processing: Image Communication · doi:10.1016/j.image.2013.05.006 · Cited by 383
Quality Assessment of Stereoscopic Images
Benoit, A., Le Callet, P., Campisi, P., & Cousseau, R. (2008) · EURASIP Journal on Image and Video Processing · doi:10.1155/2008/659024 · Cited by 374
Stereoscopic 3D-TV: Visual Comfort
Tam, W. J., Speranza, F., Yano, S., Shimono, K., & Ono, H. (2011) · IEEE Transactions on Broadcasting · doi:10.1109/tbc.2011.2125070 · Cited by 292
No-Reference Quality Assessment of Natural Stereopairs
Chen, M.-J., Cormack, L. K., & Bovik, A. C. (2013) · IEEE Transactions on Image Processing · doi:10.1109/tip.2013.2267393 · Cited by 268
Stereoscopic 3D displays and human performance: A comprehensive review
McIntire, J. P., Havig, P. R., & Geiselman, E. E. (2014) · Displays · doi:10.1016/j.displa.2013.10.004 · Cited by 225
Metadata
- Authors
- Lambooij, M. T. M., IJsselsteijn, W. A., & Heynderickx, I.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2007-02-15
- Volume
- 6490
- Pages
- 64900I
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2168297406
- Cited by
- 259
- References
- 27
- FWCI
- 14.27
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Visual discomfort in stereoscopic displays: a review. https://app.cochat.ai/papers/10.1117/12.705527
- The paper
- Lambooij, M. T. M., IJsselsteijn, W. A., & Heynderickx, I. (2007). Visual discomfort in stereoscopic displays: a review. SPIE Proceedings. https://doi.org/10.1117/12.705527
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.