Quality control of diffusion weighted images
Open accessThe DOI matches its Crossref record.
Abstract
Diffusion Tensor Imaging (DTI) has become an important MRI procedure to investigate the integrity of white matter in brain in vivo. DTI is estimated from a series of acquired Diffusion Weighted Imaging (DWI) volumes. DWI data suffers from inherent low SNR, overall long scanning time of multiple directional encoding with correspondingly large risk to encounter several kinds of artifacts. These artifacts can be too severe for a correct and stable estimation of the diffusion tensor. Thus, a quality control (QC) procedure is absolutely necessary for DTI studies. Currently, routine DTI QC procedures are conducted manually by visually checking the DWI data set in a gradient by gradient and slice by slice way. The results often suffer from low consistence across different data sets, lack of agreement of different experts, and difficulty to judge motion artifacts by qualitative inspection. Additionally considerable manpower is needed for this step due to the large number of images to QC, which is common for group comparison and longitudinal studies, especially with increasing number of diffusion gradient directions. We present a framework for automatic DWI QC. We developed a tool called DTIPrep which pipelines the QC steps with a detailed protocoling and reporting facility. And it is fully open source. This framework/tool has been successfully applied to several DTI studies with several hundred DWIs in our lab as well as collaborating labs in Utah and Iowa. In our studies, the tool provides a crucial piece for robust DTI analysis in brain white matter study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Image processing and Quality Control for the first 10,000 brain imaging datasets from UK Biobank
Alfaro-Almagro, F., Jenkinson, M., Bangerter, N. K., Andersson, J. L. R., Griffanti, L., Douaud, G., Sotiropoulos, S. N., Jbabdi, S., Hernandez-Fernandez, M., Vallee, E., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.034 · Cited by 1,557
Image processing and analysis methods for the Adolescent Brain Cognitive Development Study
Hagler, D. J., Hatton, S., Cornejo, M. D., Makowski, C., Fair, D. A., Dick, A. S., Sutherland, M. T., Casey, B. J., Barch, D. M., Harms, M. P., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116091 · Cited by 1,088
A hitchhiker's guide to diffusion tensor imaging
Soares, J. M., Marques, P., Alves, V., & Sousa, N. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00031 · Cited by 893
“Although it is already possible to find automated preprocessing pipelines (Liu et al., 2010b) (ColbyImaging, http://www . colbyimaging . com/wiki/neuroimaging/dti-preprocessing), there is no consensus over which workflow is ideal for DTI quality con-trol or preprocessing.”
BackgroundMethodInfluentialWolff, J. J., Gu, H., Gerig, G., Elison, J. T., Styner, M., Gouttard, S., Botteron, K. N., Dager, S. R., Dawson, G., Estes, A. M., et al. (2012) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2011.11091447 · Cited by 671
“DWI image data were screened for subject motion and common artifacts related to diffusion sequences using the DTIprep software (40).”
MethodSelf-citationSimmonds, D. J., Hallquist, M. N., Asato, M., & Luna, B. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.12.044 · Cited by 450
Metadata
- Authors
- Liu, Z., Wang, Y., Gerig, G., Gouttard, S., Tao, R., Fletcher, T., & Styner, M.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2010-03-04
- Volume
- 7628
- Pages
- 76280J
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W1987271059
- Cited by
- 141
- References
- 0
- FWCI
- 22.16
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quality control of diffusion weighted images. https://app.cochat.ai/papers/10.1117/12.844748
- The paper
- Liu, Z., Wang, Y., Gerig, G., Gouttard, S., Tao, R., Fletcher, T., & Styner, M. (2010). Quality control of diffusion weighted images. SPIE Proceedings. https://doi.org/10.1117/12.844748
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.