The DOI matches its Crossref record.
Effect of scattered radiation on image noise in cone beam CT
Open accessAbstract
Cone beam CT has a capability for the 3‐dimensional imaging of large volumes with isotropic resolution, and has a potentiality for 4‐dimensional imaging (dynamic volume imaging), because cone beam CT acquires data of a large volume with one rotation of an x‐ray tube‐detector pair. However, one of the potential drawbacks of cone beam CT is a larger amount of scattered x‐rays, which may enhance the noise in reconstructed images, and thus affect the low‐contrast detectablity. Our aim in this work was to estimate the scatter fractions and effects of scatter on image noise, and to seek methods of improving image quality in cone beam CT. First we derived a relationship between the noise in a reconstructed image and in an x‐ray intensity measurement. Then we estimated the scatter to primary ratios in x‐ray measurements using a Monte‐Carlo simulation. From these we estimated the image noise under relevant clinical conditions. The results showed that the scattered radiation made a substantial contribution to the image noise. However, focused collimators could improve it by decreasing the scattered radiation drastically while keeping the primary radiation at nearly the same level. A conventional grid also improved the image noise, though the improvement was less than that of focused collimators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Flat-detector computed tomography (FD-CT)
Kalender, W. A., & Kyriakou, Y. (2007) · European Radiology · doi:10.1007/s00330-007-0651-9 · Cited by 302
Paired cycle‐GAN‐based image correction for quantitative cone‐beam computed tomography
Harms, J., Lei, Y., Wang, T., Zhang, R., Zhou, J., Tang, X., Curran, W. J., Liu, T., & Yang, X. (2019) · Medical Physics · doi:10.1002/mp.13656 · Cited by 257
Sisniega, A., Zbijewski, W., Badal, A., Kyprianou, I. S., Stayman, J. W., Vaquero, J. J., & Siewerdsen, J. H. (2013) · Medical Physics · doi:10.1118/1.4801895 · Cited by 117
Metadata
- Authors
- Endo, M., Tsunoo, T., Nakamori, N., & Yoshida, K.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2001-04
- Volume
- 28
- Issue
- 4
- Pages
- 469-474
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2060712246
- Cited by
- 212
- References
- 0
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of scattered radiation on image noise in cone beam CT. https://app.cochat.ai/papers/10.1118/1.1357457
- The paper
- Endo, M., Tsunoo, T., Nakamori, N., & Yoshida, K. (2001). Effect of scattered radiation on image noise in cone beam CT. Medical Physics. https://doi.org/10.1118/1.1357457
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.