The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiology
Open accessAbstract
The American Association of Physicists in Medicine (AAPM) presents a new protocol, developed by the Radiation Therapy Committee Task Group 61, for reference dosimetry of low‐ and medium‐energy x rays for radiotherapy and radiobiology It is based on ionization chambers calibrated in air in terms of air kerma. If the point of interest is at or close to the surface, one unified approach over the entire energy range shall be used to determine absorbed dose to water at the surface of a water phantom based on an in‐air measurement (the “in‐air” method). If the point of interest is at a depth, an in‐water measurement at a depth of 2 cm shall be used for tube potentials ⩾100 kV (the “in‐phantom” method). The in‐phantom method is not recommended for tube potentials <100 kV. Guidelines are provided to determine the dose at other points in water and the dose at the surface of other biological materials of interest. The protocol is based on an up‐to‐date data set of basic dosimetry parameters, which produce consistent dose values for the two methods recommended. Estimates of uncertainties on the final dose values are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hubbell, J. H., & Seltzer, S. M. (1995) · doi:10.6028/nist.ir.5632 · Cited by 2,033
Self-citationIntroduction to Radiological Physics and Radiation Dosimetry
Attix, F. H. (1986) · Wiley eBooks · doi:10.1002/9783527617135 · Cited by 1,868
Photon mass attenuation and energy-absorption coefficients
Hubbell, J. H. (1982) · The International Journal of Applied Radiation and Isotopes · doi:10.1016/0020-708x(82)90248-4 · Cited by 1,459
Birch, R., & Marshall, M. (1979) · Physics in Medicine & Biology · doi:10.1088/0031-9155/24/3/002 · Cited by 512
Mayneord, W. V. (1944) · British Journal of Radiology · doi:10.1259/0007-1285-17-193-1 · Cited by 11
Cited by
Divergent clonal selection dominates medulloblastoma at recurrence
Morrissy, A. S., Garzia, L., Shih, D. J. H., Zuyderduyn, S., Huang, X., Skowron, P., Remke, M., Cavalli, F. M. G., Ramaswamy, V., Lindsay, P. E., et al. (2016) · Nature · doi:10.1038/nature16478 · Cited by 334
Uribe-Herranz, M., Rafail, S., Beghi, S., Gil-de-Gómez, L., Verginadis, I., Bittinger, K., Pustylnikov, S., Pierini, S., Perales-Linares, R., Blair, I. A., et al. (2019) · Journal of Clinical Investigation · doi:10.1172/jci124332 · Cited by 316
Islam, M. K., Purdie, T. G., Norrlinger, B. D., Alasti, H., Moseley, D. J., Sharpe, M. B., Siewerdsen, J. H., & Jaffray, D. A. (2006) · Medical Physics · doi:10.1118/1.2198169 · Cited by 313
Metadata
- Authors
- Ma, C. ‐., Coffey, C. W., DeWerd, L. A., Liu, C., Nath, R., Seltzer, S. M., & Seuntjens, J. P.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2001-06
- Volume
- 28
- Issue
- 6
- Pages
- 868-893
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2050718666
- Cited by
- 816
- References
- 5
- FWCI
- 11.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiology. https://app.cochat.ai/papers/10.1118/1.1374247
- The paper
- Ma, C. ‐., Coffey, C. W., DeWerd, L. A., Liu, C., Nath, R., Seltzer, S. M., & Seuntjens, J. P. (2001). AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiology. Medical Physics. https://doi.org/10.1118/1.1374247
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.