The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector
Abstract
A method of computing theoretical X-ray spectra in the range 30-150 kV is presented. The theoretical spectra are compared with constant potential, high resolution spectra from a tungsten target measured with a Ge(Li) detector, for a range of target angles, tube voltage and filtrations. Above 100 kV the spectra were also measured with a NaI detector but, as there was good agreement between the Ge(Li) and NaI detectors, only the former are presented. Spectra computed using Kramers' theory are also included for comparison, giving fairly good agreement at large target angles (30 degrees) but becoming gradually worse as the target angle decreased. Spectra may be computed by this method for any desired filtration, target angle, and tube voltage between 30 and 150 kV, in excellent agreement with the measured data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100
Storm, L., & Israel, H. I. (1970) · Atomic Data and Nuclear Data Tables · doi:10.1016/s0092-640x(70)80017-1 · Cited by 1,539
Über die Beugung und Bremsung der Elektronen
SOMMERFELD, A. (1931) · Annalen der Physik · doi:10.1002/andp.19314030302 · Cited by 777
The transmission of cathode rays through matter
Whiddington, R. (1912) · Proceedings of the Royal Society of London Series A Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1912.0028 · Cited by 141
Cited by
AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiology
Ma, C. ‐., Coffey, C. W., DeWerd, L. A., Liu, C., Nath, R., Seltzer, S. M., & Seuntjens, J. P. (2001) · Medical Physics · doi:10.1118/1.1374247 · Cited by 816
An accurate method for computer‐generating tungsten anode x‐ray spectra from 30 to 140 kV
Boone, J. M., & Seibert, J. A. (1997) · Medical Physics · doi:10.1118/1.597953 · Cited by 706
Technical aspects of dental CBCT: state of the art
Pauwels, R., Araki, K., Siewerdsen, J. H., & Thongvigitmanee, S. S. (2015) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20140224 · Cited by 510
Boone, J. M., Fewell, T. R., & Jennings, R. J. (1997) · Medical Physics · doi:10.1118/1.598100 · Cited by 452
X-irradiation of cells on glass slides has a dose doubling impact
Kegel, P., Riballo, E., Kühne, M., Jeggo, P. A., & Löbrich, M. (2007) · DNA Repair · doi:10.1016/j.dnarep.2007.05.013 · Cited by 55
Metadata
- Authors
- Birch, R., & Marshall, M.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 1979-05-01
- Volume
- 24
- Issue
- 3
- Pages
- 505-517
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2038259880
- Cited by
- 512
- References
- 3
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector. https://app.cochat.ai/papers/10.1088/0031-9155/24/3/002
- The paper
- Birch, R., & Marshall, M. (1979). Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector. Physics in Medicine & Biology. https://doi.org/10.1088/0031-9155/24/3/002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.