Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 233

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Quantification of the degree of mineralization of bone in three dimensions using synchrotron radiation microtomography

Nuzzo, Stefania, Peyrin, Françoise, Cloetens, Peter, Baruchel, José, Boivin, Georges · 2002 · Medical Physics

Abstract

The availability of three‐dimensional measuring techniques coupled to specific image processing methods opens new opportunities for the analysis of bone structure. In particular, synchrotron radiation microtomography may provide three‐dimensional images with spatial resolution as high as one micrometer. Moreover, the use of a monoenergetic synchrotron beam, which avoids beam‐hardening effects, allows quantitative measurements of the degree of mineralization in bone samples. Indeed, the reconstructed gray levels of tomographic images correspond directly to a map of the linear attenuation coefficient within the sample. Since the absorption depends on the amount of mineral content, we proposed a calibration method to evaluate the three‐dimensional distribution of the degree of mineralization within the sample. First a theoretical linear relationship modeling the linear attenuation coefficient as a function of the hydroxyapatite concentrations was derived. Then, an experimental validation on phantoms confirmed both the accuracy of the image processing tools and the experimental setup used. Finally, the analysis of the degree of mineralization in four iliac crest bone biopsy samples was reported. Our method was compared to the reference microradiography technique, currently used for this quantification in two dimensions. The concentration values of the degree of mineralization were found with both techniques in the range 0.5–1.6 g of mineral per cubic centimeter of bone, both in cortical and in trabecular region. The mean difference between the two techniques was around 4.7%, and was slightly higher in trabecular region than in cortical bone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.1513161

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 233

Metadata

Authors
Nuzzo, S., Peyrin, F., Cloetens, P., Baruchel, J., & Boivin, G.
Venue
Medical Physics
Publisher
Wiley
Published
2002-10-28
Volume
29
Issue
11
Pages
2672-2681
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W1996767999
Cited by
233
References
2
FWCI
8.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of the degree of mineralization of bone in three dimensions using synchrotron radiation microtomography. https://app.cochat.ai/papers/10.1118/1.1513161
The paper
Nuzzo, S., Peyrin, F., Cloetens, P., Baruchel, J., & Boivin, G. (2002). Quantification of the degree of mineralization of bone in three dimensions using synchrotron radiation microtomography. Medical Physics. https://doi.org/10.1118/1.1513161

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.