The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Selective enhancement filters for nodules, vessels, and airway walls in two‐ and three‐dimensional CT scans
Abstract
Computer‐aided diagnostic (CAD) schemes have been developed to assist radiologists in the early detection of lung cancer in radiographs and computed tomography (CT) images. In order to improve sensitivity for nodule detection, many researchers have employed a filter as a preprocessing step for enhancement of nodules. However, these filters enhance not only nodules, but also other anatomic structures such as ribs, blood vessels, and airway walls. Therefore, nodules are often detected together with a large number of false positives caused by these normal anatomic structures. In this study, we developed three selective enhancement filters for dot, line, and plane which can simultaneously enhance objects of a specific shape (for example, dot‐like nodules) and suppress objects of other shapes (for example, line‐like vessels). Therefore, as preprocessing steps, these filters would be useful for improving the sensitivity of nodule detection and for reducing the number of false positives. We applied our enhancement filters to synthesized images to demonstrate that they can selectively enhance a specific shape and suppress other shapes. We also applied our enhancement filters to real two‐dimensional (2D) and three‐dimensional (3D) CT images to show their effectiveness in the enhancement of specific objects in real medical images. We believe that the three enhancement filters developed in this study would be useful in the computerized detection of cancer in 2D and 3D medical images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Greenlee, R. T., Murray, T., Bolden, S., & Wingo, P. A. (2000) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.50.1.7 · Cited by 3,850
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
Koenderink, J. J. (1984) · Biological Cybernetics · doi:10.1007/bf00336961 · Cited by 2,452
Scale-Space Theory in Computer Vision
Lindeberg, T. (1994) · Springer eBooks · doi:10.1007/978-1-4757-6465-9 · Cited by 2,169
Sato, Y., Nakajima, S., Shiraga, N., Atsumi, H., Yoshida, S., Koller, T., Gerig, G., & Kikinis, R. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80009-1 · Cited by 1,163
Mass screening for lung cancer with mobile spiral computed tomography scanner
Sone, S., Takashima, S., Li, F., Yang, Z., Honda, T., Maruyama, Y., Hasegawa, M., Yamanda, T., Kubo, K., Hanamura, K., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)08229-9 · Cited by 931
Self-citationSone, S., Li, F., Yang, Z.-G., Honda, T., Maruyama, Y., Takashima, S., Hasegawa, M., Kawakami, S., Kubo, K., Haniuda, M., et al. (2001) · British Journal of Cancer · doi:10.1054/bjoc.2000.1531 · Cited by 495
Self-citationLee, Y., Hara, T., Fujita, H., Itoh, S., & Ishigaki, T. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932744 · Cited by 457
Model-based quantitation of 3-D magnetic resonance angiographic images
Frangi, A. F., Niessen, W. J., Hoogeveen, R. M., van Walsum, T., & Viergever, M. A. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811279 · Cited by 383
Computerized Detection of Pulmonary Nodules on CT Scans
Armato, S. G., Giger, M. L., Moran, C. J., Blackburn, J. T., Doi, K., & MacMahon, H. (1999) · Radiographics · doi:10.1148/radiographics.19.5.g99se181303 · Cited by 380
Self-citation
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
Self-citation
Metadata
- Authors
- Li, Q., Sone, S., & Doi, K.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2003-07-14
- Volume
- 30
- Issue
- 8
- Pages
- 2040-2051
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1971997700
- Cited by
- 349
- References
- 19
- FWCI
- 8.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective enhancement filters for nodules, vessels, and airway walls in two‐ and three‐dimensional CT scans. https://app.cochat.ai/papers/10.1118/1.1581411
- The paper
- Li, Q., Sone, S., & Doi, K. (2003). Selective enhancement filters for nodules, vessels, and airway walls in two‐ and three‐dimensional CT scans. Medical Physics. https://doi.org/10.1118/1.1581411
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.