The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Open accessAbstract
This document is the report of a task group of the AAPM and has been prepared primarily to advise medical physicists involved in the external‐beam radiation therapy of patients with thoracic, abdominal, and pelvic tumors affected by respiratory motion. This report describes the magnitude of respiratory motion, discusses radiotherapy specific problems caused by respiratory motion, explains techniques that explicitly manage respiratory motion during radiotherapy and gives recommendations in the application of these techniques for patient care, including quality assurance (QA) guidelines for these devices and their use with conformal and intensity modulated radiotherapy. The technologies covered by this report are motion‐encompassing methods, respiratory gated techniques, breath‐hold techniques, forced shallow‐breathing methods, and respiration‐synchronized techniques. The main outcome of this report is a clinical process guide for managing respiratory motion. Included in this guide is the recommendation that tumor motion should be measured (when possible) for each patient for whom respiratory motion is a concern. If target motion is greater than , a method of respiratory motion management is available, and if the patient can tolerate the procedure, respiratory motion management technology is appropriate. Respiratory motion management is also appropriate when the procedure will increase normal tissue sparing. Respiratory motion management involves further resources, education and the development of and adherence to QA procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prescribing, recording, and reporting photon beam therapy
Icru (1993) · Medical Entomology and Zoology · Cited by 1,996
van Herk, M., Remeijer, P., Rasch, C., & Lebesque, J. V. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00518-6 · Cited by 1,531
Self-citationSeppenwoolde, Y., Shirato, H., Kitamura, K., Shimizu, S., van Herk, M., Lebesque, J. V., & Miyasaka, K. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02803-1 · Cited by 1,379
Graham, M. V., Purdy, J. A., Emami, B., Harms, W., Bosch, W., Lockett, M. A., & Perez, C. A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00183-2 · Cited by 1,223
The use of active breathing control (ABC) to reduce margin for breathing motion
Wong, J. W., Sharpe, M. B., Jaffray, D. A., Kini, V. R., Robertson, J. M., Stromberg, J. S., & Martinez, A. A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00056-5 · Cited by 912
Self-citationBlomgren, H., Lax, I., Näslund, I., & Svanström, R. (1995) · Acta Oncologica · doi:10.3109/02841869509127197 · Cited by 846
Radiation pneumonitis as a function of mean lung dose: an analysis of pooled data of 540 patients
Kwa, S. L. S., Lebesque, J. V., Theuws, J. C. M., Marks, L. B., Munley, M. T., Bentel, G., Oetzel, D., Spahn, U., Graham, M. V., Drzymala, R. E., et al. (1998) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00196-5 · Cited by 750
Extracranial Stereotactic Radioablation *
Timmerman, R., Papiez, L., McGarry, R., Likes, L., DesRosiers, C., Frost, S., & Williams, M. (2003) · Chest · doi:10.1378/chest.124.5.1946 · Cited by 671
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
Shirato, H., Shimizu, S., Kunieda, T., Kitamura, K., van Herk, M., Kagei, K., Nishioka, T., Hashimoto, S., Fujita, K., Aoyama, H., et al. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00748-3 · Cited by 662
Self-citationRespiration gated radiotherapy treatment: a technical study
Kubo, H., & Hill, B. C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/007 · Cited by 636
Cited by
Stereotactic body radiation therapy: The report of AAPM Task Group 101
Benedict, S. H., Yenice, K. M., Followill, D., Galvin, J. M., Hinson, W., Kavanagh, B., Keall, P., Lovelock, M., Meeks, S., Papiez, L., et al. (2010) · Medical Physics · doi:10.1118/1.3438081 · Cited by 2,218
Self-citation_, _. (2008) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2008.0021 · Cited by 735
Ettinger, D. S., Akerley, W., Bepler, G., Blum, M. G., Chang, A., Cheney, R. T., Chirieac, L. R., D'Amico, T. A., Demmy, T. L., Ganti, A. K. P., et al. (2010) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2010.0056 · Cited by 730
Image-guided radiotherapy: from current concept to future perspectives
Jaffray, D. A. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.194 · Cited by 496
Respiratory motion models: A review
McClelland, J. R., Hawkes, D. J., Schaeffter, T., & King, A. P. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.09.005 · Cited by 385
Innovations in image-guided radiotherapy
Verellen, D., Ridder, M. D., Linthout, N., Tournel, K., Soete, G., & Storme, G. (2007) · Nature Reviews Cancer · doi:10.1038/nrc2288 · Cited by 384
De Ruysscher, D., Faivre-Finn, C., Nestle, U., Hurkmans, C. W., Le Péchoux, C., Price, A., & Senan, S. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2010.30.3271 · Cited by 364
Hoogeman, M., Prévost, J.-B., Nuyttens, J., Pöll, J., Levendag, P., & Heijmen, B. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.12.041 · Cited by 327
4D MR imaging of respiratory organ motion and its variability
Siebenthal, M. V., Székely, G., Gamper, U., Boesiger, P., Lomax, A., & Cattin, P. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/001 · Cited by 324
Vandewinckele, L., Claessens, M., Dinkla, A., Brouwer, C., Crijns, W., Verellen, D., & van Elmpt, W. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.09.008 · Cited by 321
Adaptive Radiotherapy for Anatomical Changes
Sonke, J.-J., Aznar, M., & Rasch, C. (2019) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2019.02.007 · Cited by 301
Markerless Pancreatic Tumor Target Localization Enabled By Deep Learning
Zhao, W., Shen, L., Han, B., Yang, Y., Cheng, K., Toesca, D. A. S., Koong, A. C., Chang, D. T., & Xing, L. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2019.05.071 · Cited by 88
Predicting Respiratory Motion for Real-Time Tumour Tracking in Radiotherapy
Krilavicius, T., Zliobaite, I., Simonavicius, H., & Jaruevicius, L. (2016) · 2016 IEEE 29th International Symposium on Computer-Based Medical Systems (CBMS) · doi:10.1109/cbms.2016.52 · Cited by 15
Metadata
- Authors
- Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., Kapatoes, J. M., Low, D. A., Murphy, M. J., Murray, B. R., Ramsey, C. R., Van Herk, M. B., Vedam, S. S., Wong, J. W., & Yorke, E.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2006-09-26
- Volume
- 33
- Issue
- 10
- Pages
- 3874-3900
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2127480863
- Cited by
- 2,327
- References
- 57
- FWCI
- 63.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.