CoChat

Hyperfast parallel‐beam and cone‐beam backprojection using the cell general purpose hardware

Kachelrieß, Marc, Knaup, Michael, Bockenbach, Olivier · 2007 · Medical Physics
Cited by 96

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Tomographic image reconstruction, such as the reconstruction of computed tomography projection values, of tomosynthesis data, positron emission tomography or SPECT events, and of magnetic resonance imaging data is computationally very demanding. One of the most time‐consuming steps is the backprojection. Recently, a novel general purpose architecture optimized for distributed computing became available: the cell broadband engine (CBE). To maximize image reconstruction speed we modified our parallel‐beam backprojection algorithm [two dimensional (2D)] and our perspective backprojection algorithm [three dimensional (3D), cone beam for flat–panel detectors] and optimized the code for the CBE. The algorithms are pixel or voxel driven, run with floating point accuracy and use linear (LI) or nearest neighbor (NN) interpolation between detector elements. For the parallel‐beam case, 512 projections per half rotation, 1024 detector channels, and an image of size was used. The cone‐beam backprojection performance was assessed by backprojecting a full circle scan of 512 projections of size into a volume of size voxels. The field of view was chosen to completely lie within the field of measurement and the pixel or voxel size was set to correspond to the detector element size projected to the center of rotation divided by. Both the PC and the CBE were clocked at. For the parallel backprojection of 512 projections into a image, a throughput of(LI) and(NN) was measured on the PC, whereas the CBE achieved(LI) and(NN), respectively. The cone‐beam backprojection of 512 projections into the volume took on the PC and is as fast as on the cell. Thereby, the cell greatly outperforms today's top‐notch backprojections based on graphical processing units. Using both CBEs of our dual cell‐based blade (Mercury Computer Systems) allows to 2D backproject 330 images/s and one can complete the 3D cone‐beam backprojection in.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.2710328

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 96

Metadata

Authors
Kachelrieß, M., Knaup, M., & Bockenbach, O.
Venue
Medical Physics
Publisher
Wiley
Published
2007-03-27
Volume
34
Issue
4
Pages
1474-1486
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2082344075
Cited by
96
References
1
FWCI
34.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hyperfast parallel‐beam and cone‐beam backprojection using the cell general purpose hardware. https://app.cochat.ai/papers/10.1118/1.2710328
The paper
Kachelrieß, M., Knaup, M., & Bockenbach, O. (2007). Hyperfast parallel‐beam and cone‐beam backprojection using the cell general purpose hardware. Medical Physics. https://doi.org/10.1118/1.2710328

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.