Hyperfast parallel‐beam and cone‐beam backprojection using the cell general purpose hardware
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Tomographic image reconstruction, such as the reconstruction of computed tomography projection values, of tomosynthesis data, positron emission tomography or SPECT events, and of magnetic resonance imaging data is computationally very demanding. One of the most time‐consuming steps is the backprojection. Recently, a novel general purpose architecture optimized for distributed computing became available: the cell broadband engine (CBE). To maximize image reconstruction speed we modified our parallel‐beam backprojection algorithm [two dimensional (2D)] and our perspective backprojection algorithm [three dimensional (3D), cone beam for flat–panel detectors] and optimized the code for the CBE. The algorithms are pixel or voxel driven, run with floating point accuracy and use linear (LI) or nearest neighbor (NN) interpolation between detector elements. For the parallel‐beam case, 512 projections per half rotation, 1024 detector channels, and an image of size was used. The cone‐beam backprojection performance was assessed by backprojecting a full circle scan of 512 projections of size into a volume of size voxels. The field of view was chosen to completely lie within the field of measurement and the pixel or voxel size was set to correspond to the detector element size projected to the center of rotation divided by. Both the PC and the CBE were clocked at. For the parallel backprojection of 512 projections into a image, a throughput of(LI) and(NN) was measured on the PC, whereas the CBE achieved(LI) and(NN), respectively. The cone‐beam backprojection of 512 projections into the volume took on the PC and is as fast as on the cell. Thereby, the cell greatly outperforms today's top‐notch backprojections based on graphical processing units. Using both CBEs of our dual cell‐based blade (Mercury Computer Systems) allows to 2D backproject 330 images/s and one can complete the 3D cone‐beam backprojection in.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Cited by
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Pan, X., Sidky, E. Y., & Vannier, M. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123009 · Cited by 572
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT
Bian, J., Siewerdsen, J. H., Han, X., Sidky, E. Y., Prince, J. L., Pelizzari, C. A., & Pan, X. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/001 · Cited by 373
Improved total variation-based CT image reconstruction applied to clinical data
Ritschl, L., Bergner, F., Fleischmann, C., & Kachelrieß, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/6/003 · Cited by 306
Self-citation
Metadata
- Authors
- Kachelrieß, M., Knaup, M., & Bockenbach, O.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2007-03-27
- Volume
- 34
- Issue
- 4
- Pages
- 1474-1486
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2082344075
- Cited by
- 96
- References
- 1
- FWCI
- 34.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hyperfast parallel‐beam and cone‐beam backprojection using the cell general purpose hardware. https://app.cochat.ai/papers/10.1118/1.2710328
- The paper
- Kachelrieß, M., Knaup, M., & Bockenbach, O. (2007). Hyperfast parallel‐beam and cone‐beam backprojection using the cell general purpose hardware. Medical Physics. https://doi.org/10.1118/1.2710328
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.