The DOI matches its Crossref record.
Iterative image reconstruction for CBCT using edge‐preserving prior
Open accessAbstract
On‐board cone‐beam computed tomography (CBCT) is a new imaging technique for radiation therapy guidance, which provides volumetric information of a patient at treatment position. CBCT improves the setup accuracy and may be used for dose reconstruction. However, there is great concern that the repeated use of CBCT during a treatment course delivers too much of an extra dose to the patient. To reduce the CBCT dose, one needs to lower the total mAs of the x‐ray tube current, which usually leads to reduced image quality. Our goal of this work is to develop an effective method that enables one to achieve a clinically acceptable CBCT image with as low as possible mAs without compromising quality. An iterative image reconstruction algorithm based on a penalized weighted least‐squares (PWLS) principle was developed for this purpose. To preserve edges in the reconstructed images, we designed an anisotropic penalty term of a quadratic form. The algorithm was evaluated with a CT quality assurance phantom and an anthropomorphic head phantom. Compared with conventional isotropic penalty, the PWLS image reconstruction algorithm with anisotropic penalty shows better resolution preservation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artifact Suppressed Dictionary Learning for Low-Dose CT Image Processing
Chen, Y., Shi, L., Feng, Q., Yang, J., Shu, H., Luo, L., Coatrieux, J.-L., & Chen, W. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2336860 · Cited by 315
Sparse-view x-ray CT reconstruction via total generalized variation regularization
Niu, S., Gao, Y., Bian, Z., Huang, J., Chen, W., Yu, G., Liang, Z., & Ma, J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/12/2997 · Cited by 291
Tang, J., Nett, B. E., & Chen, G.-H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/008 · Cited by 282
Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order methoda)
Choi, K., Wang, J., Zhu, L., Suh, T., Boyd, S., & Xing, L. (2010) · Medical Physics · doi:10.1118/1.3481510 · Cited by 255
Self-citationNoise correlation in CBCT projection data and its application for noise reduction in low‐dose CBCT
Zhang, H., Ouyang, L., Ma, J., Huang, J., Chen, W., & Wang, J. (2014) · Medical Physics · doi:10.1118/1.4865782 · Cited by 47
Self-citation
Metadata
- Authors
- Wang, J., Li, T., & Xing, L.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2008-12-29
- Volume
- 36
- Issue
- 1
- Pages
- 252-260
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2040189727
- Cited by
- 188
- References
- 0
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Iterative image reconstruction for CBCT using edge‐preserving prior. https://app.cochat.ai/papers/10.1118/1.3036112
- The paper
- Wang, J., Li, T., & Xing, L. (2009). Iterative image reconstruction for CBCT using edge‐preserving prior. Medical Physics. https://doi.org/10.1118/1.3036112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.