CoChat

Patient‐specific finite element modeling of respiratory lung motion using 4D CT image data

Open access
Werner, René, Ehrhardt, Jan, Schmidt, Rainer, Handels, Heinz · 2009 · Medical Physics
Cited by 160

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

Development and optimization of methods for adequately accounting for respiratory motion in radiation therapy of thoracic tumors require detailed knowledge of respiratory dynamics and its impact on corresponding dose distributions. Thus, computer aided modeling and simulation of respiratory motion have become increasingly important. In this article a biophysical approach for modeling respiratory lung motion is described: Major aspects of the process of lung ventilation are formulated as a contact problem of elasticity theory which is solved by finite element methods; lung tissue is assumed to be isotropic, homogeneous, and linearly elastic. A main focus of the article is to assess the impact of biomechanical parameters (values of elastic constants) on the modeling process and to evaluate modeling accuracy. Patient‐specific models are generated based on 4D CT data of 12 lung tumor patients. Simulated motion patterns of inner lung landmarks are compared with corresponding motion patterns observed in the 4D CT data. Mean absolute differences between model‐based predicted landmark motion and corresponding breathing‐induced landmark displacements as observed in the CT data sets are in the order of (end expiration to end inspiration) and (end expiration to midrespiration). Modeling accuracy decreases with increasing tumor size both locally (landmarks close to tumor) and globally (landmarks in other parts of the lung). The impact of the values of the elastic constants appears to be small. Outcomes show that the modeling approach is an adequate strategy in predicting lung dynamics due to lung ventilation. Nevertheless, the decreased prediction quality in cases of large tumors demands further study of the influence of lung tumors on global and local lung elasticity properties.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3101820

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

Metadata

Authors
Werner, R., Ehrhardt, J., Schmidt, R., & Handels, H.
Venue
Medical Physics
Publisher
Wiley
Published
2009-04-07
Volume
36
Issue
5
Pages
1500-1511
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2028662175
Cited by
160
References
32
FWCI
8.62
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).