The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measurement of MRI scanner performance with the ADNI phantom
Open accessAbstract
The objectives of this study are as follows: to describe practical implementation challenges of multisite, multivendor quantitative studies; to describe the MRI phantom and analysis software used in the Alzheimer's Disease Neuroimaging Initiative (ADNI) study, illustrate the utility of the system for measuring scanner performance, the ability to assess gradient field nonlinearity corrections: and to recover human brain images without geometric scaling errors in multisite studies. ADNI is a large multicenter study with each center having its own copy of the phantom. The design of the phantom and analysis software are presented as results from predistribution systematics studies and results from field experience with the phantom at 58 enrolling ADNI sites over a period. The estimated coefficients of variation intrinsic to measurements of geometry in a single phantom are in the range of 3–5 parts in . Phantom measurements accurately detect linear and nonlinear scaling in images. Gradient unwarping methods are readily assessed by phantom nonlinearity measurements. Phantom‐based scaling correction reduces observed geometric drift in human images by one‐third or more. Repair or replacement of phantoms between scans, however, is a confounding factor. The ADNI phantom can be used to assess both scanner performance and the validity of postprocessing image corrections in order to reduce systematic errors in human images. Reduced measurement errors should decrease measurement bias and increase statistical power for measurements of rates of change in the brain structure in AD treatment trials. Perhaps the greatest practical value of incorporating ADNI phantom measurements in a multisite study is to identify scanner errors through central monitoring. This approach has resulted in identification of system errors including sites misidentification of their own gradient hardware and the disabling of autoshim, and a miscalibrated laser alignment light. If undetected, these errors would have contributed to imprecision in quantitative metrics at over 25% of all enrolling ADNI sites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Alzheimer’s disease neuroimaging initiative (ADNI): MRI methods
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., Borowski, B., Britson, P. J., L. Whitwell, J., Ward, C., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21049 · Cited by 4,347
Cited by
The Alzheimer's Disease Neuroimaging Initiative: A review of papers published since its inception
Weiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Green, R. C., Harvey, D., Jack, C. R., Jagust, W., Liu, E., et al. (2013) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2013.05.1769 · Cited by 1,010
Self-citationJack, C. R., Knopman, D. S., Weigand, S. D., Wiste, H. J., Vemuri, P., Lowe, V., Kantarci, K., Gunter, J. L., Senjem, M. L., Ivnik, R. J., et al. (2012) · Annals of Neurology · doi:10.1002/ana.22628 · Cited by 602
Self-citationCannon, T. D., Chung, Y., He, G., Sun, D., Jacobson, A., van Erp, T. G. M., McEwen, S., Addington, J., Bearden, C. E., Cadenhead, K., et al. (2015) · Biological Psychiatry · doi:10.1016/j.biopsych.2014.05.023 · Cited by 599
The Alzheimer's Disease Neuroimaging Initiative: Progress report and future plans
Weiner, M. W., Aisen, P. S., Jack, C. R., Jagust, W. J., Trojanowski, J. Q., Shaw, L., Saykin, A. J., Morris, J. C., Cairns, N., Beckett, L. A., et al. (2010) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2010.03.007 · Cited by 599
Self-citationThe Alzheimer's Disease Neuroimaging Initiative: A review of papers published since its inception
Weiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Green, R. C., Harvey, D., Jack, C. R., Jagust, W., Liu, E., et al. (2012) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2011.09.172 · Cited by 476
Self-citationUpdate on the Magnetic Resonance Imaging core of the Alzheimer's Disease Neuroimaging Initiative
Jack, C. R., Bernstein, M. A., Borowski, B. J., Gunter, J. L., Fox, N. C., Thompson, P. M., Schuff, N., Krueger, G., Killiany, R. J., DeCarli, C. S., et al. (2010) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2010.03.004 · Cited by 378
Self-citationWeiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Cedarbaum, J., Green, R. C., Harvey, D., Jack, C. R., Jagust, W., et al. (2015) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2014.11.001 · Cited by 348
Self-citationLongitudinal ComBat: A method for harmonizing longitudinal multi-scanner imaging data
Beer, J. C., Tustison, N. J., Cook, P. A., Davatzikos, C., Sheline, Y. I., Shinohara, R. T., & Linn, K. A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117129 · Cited by 319
Predicting clinical scores from magnetic resonance scans in Alzheimer's disease
Stonnington, C. M., Chu, C., Klöppel, S., Jack, C. R., Ashburner, J., & Frackowiak, R. S. J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.051 · Cited by 257
Self-citationMagnetic resonance imaging in Alzheimer’s disease neuroimaging initiative 2
Jack, C. R., Barnes, J., Bernstein, M. A., Borowski, B. J., Brewer, J., Clegg, S., Dale, A. M., Carmichael, O., Ching, C., DeCarli, C., et al. (2015) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2015.05.002 · Cited by 220
Self-citationEarly cerebral small vessel disease and brain volume, cognition, and gait
Smith, E. E., O'Donnell, M., Dagenais, G., Lear, S. A., Wielgosz, A., Sharma, M., Poirier, P., Stotts, G., Black, S. E., Strother, S., et al. (2015) · Annals of Neurology · doi:10.1002/ana.24320 · Cited by 207
“The Alzheimer’s Disease Neuroimaging Initiative (ADNI) phantom was scanned at each site at study initiation and termination to quantitatively estimate betweensite and within-site differences.(12) Additionally, scan quality was centrally reviewed by a neurologist (E.”
MethodAssociation of type 2 diabetes with brain atrophy and cognitive impairment
Roberts, R. O., Knopman, D. S., Przybelski, S. A., Mielke, M. M., Kantarci, K., Preboske, G. M., Senjem, M. L., Pankratz, V. S., Geda, Y. E., Boeve, B. F., et al. (2014) · Neurology · doi:10.1212/wnl.0000000000000269 · Cited by 211
Self-citationBrain injury biomarkers are not dependent on β‐amyloid in normal elderly
Knopman, D. S., Jack, C. R., Wiste, H. J., Weigand, S. D., Vemuri, P., Lowe, V. J., Kantarci, K., Gunter, J. L., Senjem, M. L., Mielke, M. M., et al. (2013) · Annals of Neurology · doi:10.1002/ana.23816 · Cited by 183
Self-citationShapes of the Trajectories of 5 Major Biomarkers of Alzheimer Disease
Jack, C. R., Vemuri, P., Wiste, H. J., Weigand, S. D., Lesnick, T. G., Lowe, V., Kantarci, K., Bernstein, M. A., Senjem, M. L., Gunter, J. L., et al. (2012) · Archives of Neurology · doi:10.1001/archneurol.2011.3405 · Cited by 145
Self-citationA computational model of neurodegeneration in Alzheimer’s disease
Jones, D., Lowe, V., Graff-Radford, J., Botha, H., Barnard, L., Wiepert, D., Murphy, M. C., Murray, M., Senjem, M., Gunter, J., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-29047-4 · Cited by 78
Self-citationKnopman, D. S., Jack, C. R., Wiste, H. J., Weigand, S. D., Vemuri, P., Lowe, V. J., Kantarci, K., Gunter, J. L., Senjem, M. L., Mielke, M. M., et al. (2013) · JAMA Neurology · doi:10.1001/jamaneurol.2013.182 · Cited by 68
Self-citation
Metadata
- Authors
- Gunter, J. L., Bernstein, M. A., Borowski, B. J., Ward, C. P., Britson, P. J., Felmlee, J. P., Schuff, N., Weiner, M., & Jack, C. R.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2009-05-13
- Volume
- 36
- Issue
- 6Part1
- Pages
- 2193-2205
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2027237000
- Cited by
- 172
- References
- 1
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.