Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 208

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Noise injection for training artificial neural networks: A comparison with weight decay and early stopping

Open access
Zur, Richard M., Jiang, Yulei, Pesce, Lorenzo L., Drukker, Karen·2009·Medical Physics

Abstract

The purpose of this study was to investigate the effect of a noise injection method on the “overfitting” problem of artificial neural networks (ANNs) in two‐class classification tasks. The authors compared ANNs trained with noise injection to ANNs trained with two other methods for avoiding overfitting: weight decay and early stopping. They also evaluated an automatic algorithm for selecting the magnitude of the noise injection. They performed simulation studies of an exclusive‐or classification task with training datasets of 50, 100, and 200 cases (half normal and half abnormal) and an independent testing dataset of 2000 cases. They also compared the methods using a breast ultrasound dataset of 1126 cases. For simulated training datasets of 50 cases, the area under the receiver operating characteristic curve (AUC) was greater (by 0.03) when training with noise injection than when training without any regularization, and the improvement was greater than those from weight decay and early stopping (both of 0.02). For training datasets of 100 cases, noise injection and weight decay yielded similar increases in the AUC (0.02), whereas early stopping produced a smaller increase (0.01). For training datasets of 200 cases, the increases in the AUC were negligibly small for all methods (0.005). For the ultrasound dataset, noise injection had a greater average AUC than ANNs trained without regularization and a slightly greater average AUC than ANNs trained with weight decay. These results indicate that training ANNs with noise injection can reduce overfitting to a greater degree than early stopping and to a similar degree as weight decay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3213517

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 208

Metadata

Authors
Zur, R. M., Jiang, Y., Pesce, L. L., & Drukker, K.
Venue
Medical Physics
Publisher
Wiley
Published
2009-09-25
Volume
36
Issue
10
Pages
4810-4818
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2030214786
Cited by
208
References
5
FWCI
2.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noise injection for training artificial neural networks: A comparison with weight decay and early stopping. https://app.cochat.ai/papers/10.1118/1.3213517
The paper
Zur, R. M., Jiang, Y., Pesce, L. L., & Drukker, K. (2009). Noise injection for training artificial neural networks: A comparison with weight decay and early stopping. Medical Physics. https://doi.org/10.1118/1.3213517

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.