The DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Stereotactic body radiation therapy: The report of AAPM Task Group 101
Abstract
Task Group 101 of the AAPM has prepared this report for medical physicists, clinicians, and therapists in order to outline the best practice guidelines for the external‐beam radiation therapy technique referred to as stereotactic body radiation therapy (SBRT). The task group report includes a review of the literature to identify reported clinical findings and expected outcomes for this treatment modality. Information is provided for establishing a SBRT program, including protocols, equipment, resources, and QA procedures. Additionally, suggestions for developing consistent documentation for prescribing, reporting, and recording SBRT treatment delivery is provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Randomized Trial of Surgery in the Treatment of Single Metastases to the Brain
Patchell, R. A., Tibbs, P. A., Walsh, J. W., Dempsey, R. J., Maruyama, Y., Kryscio, R. J., Markesbery, W. R., Macdonald, J. S., & Young, B. (1990) · New England Journal of Medicine · doi:10.1056/nejm199002223220802 · Cited by 3,135
Hellman, S., & Weichselbaum, R. R. (1995) · Journal of Clinical Oncology · doi:10.1200/jco.1995.13.1.8 · Cited by 2,562
Andrews, D. W., Scott, C. B., Sperduto, P. W., Flanders, A. E., Gaspar, L. E., Schell, M. C., Werner-Wasik, M., Demas, W., Ryu, J., Bahary, J.-P., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16250-8 · Cited by 2,417
Self-citationThe management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., Kapatoes, J. M., Low, D. A., Murphy, M. J., Murray, B. R., et al. (2006) · Medical Physics · doi:10.1118/1.2349696 · Cited by 2,327
Self-citationPrescribing, recording, and reporting photon beam therapy
Icru (1993) · Medical Entomology and Zoology · Cited by 1,996
Timmerman, R., McGarry, R., Yiannoutsos, C., Papiez, L., Tudor, K., DeLuca, J., Ewing, M., Abdulrahman, R., DesRosiers, C., Williams, M., et al. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2006.07.5937 · Cited by 1,556
Self-citationLong-term results of lung metastasectomy: Prognostic analyses based on 5206 cases
Pastorino, U., Buyse, M., Friedel, G., Ginsberg, R. J., Girard, P., Goldstraw, P., Johnston, M., McCormack, P., Pass, H., & Putnam, J. B. (1997) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70397-0 · Cited by 1,529
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
Seppenwoolde, Y., Shirato, H., Kitamura, K., Shimizu, S., van Herk, M., Lebesque, J. V., & Miyasaka, K. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02803-1 · Cited by 1,379
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Cited by
Ost, P., Reynders, D., Decaestecker, K., Fonteyne, V., Lumen, N., De Bruycker, A., Lambert, B., Delrue, L., Bultijnck, R., Claeys, T., et al. (2018) · Journal of Clinical Oncology · doi:10.1200/jco.2017.75.4853 · Cited by 1,351
Phillips, R., Shi, W. Y., Deek, M., Radwan, N., Lim, S. J., Antonarakis, E. S., Rowe, S. P., Ross, A. E., Gorin, M. A., Deville, C., et al. (2020) · JAMA Oncology · doi:10.1001/jamaoncol.2020.0147 · Cited by 1,159
Self-citation_, _. (2008) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2008.0021 · Cited by 735
Noninvasive Cardiac Radiation for Ablation of Ventricular Tachycardia
Cuculich, P. S., Schill, M. R., Kashani, R., Mutic, S., Lang, A., Cooper, D., Faddis, M., Gleva, M., Noheria, A., Smith, T. W., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1613773 · Cited by 660
Stereotactic body radiotherapy for oligometastases
Tree, A. C., Khoo, V. S., Eeles, R. A., Ahmed, M., Dearnaley, D. P., Hawkins, M. A., Huddart, R. A., Nutting, C. M., Ostler, P. J., & van As, N. J. (2013) · The Lancet Oncology · doi:10.1016/s1470-2045(12)70510-7 · Cited by 524
Milano, M. T., Katz, A. W., Zhang, H., & Okunieff, P. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2011.08.036 · Cited by 439
Robinson, C. G., Samson, P. P., Moore, K. M. S., Hugo, G. D., Knutson, N., Mutic, S., Goddu, S. M., Lang, A., Cooper, D. H., Faddis, M., et al. (2019) · Circulation · doi:10.1161/circulationaha.118.038261 · Cited by 425
Single- and Multifraction Stereotactic Radiosurgery Dose/Volume Tolerances of the Brain
Milano, M. T., Grimm, J., Niemierko, A., Soltys, S. G., Moiseenko, V., Redmond, K. J., Yorke, E., Sahgal, A., Xue, J., Mahadevan, A., et al. (2021) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2020.08.013 · Cited by 402
Bissonnette, J., Balter, P. A., Dong, L., Langen, K. M., Lovelock, D. M., Miften, M., Moseley, D. J., Pouliot, J., Sonke, J., & Yoo, S. (2012) · Medical Physics · doi:10.1118/1.3690466 · Cited by 359
Altorki, N. K., McGraw, T. E., Borczuk, A. C., Saxena, A., Port, J. L., Stiles, B. M., Lee, B. E., Sanfilippo, N. J., Scheff, R. J., Pua, B. B., et al. (2021) · The Lancet Oncology · doi:10.1016/s1470-2045(21)00149-2 · Cited by 342
Adaptive Radiotherapy for Anatomical Changes
Sonke, J.-J., Aznar, M., & Rasch, C. (2019) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2019.02.007 · Cited by 301
Zheng, X., Schipper, M., Kidwell, K., Lin, J., Reddy, R., Ren, Y., Chang, A., Lv, F., Orringer, M., & Spring Kong, F.-M. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.05.055 · Cited by 256
Repeated stereotactic body radiotherapy for oligometastatic prostate cancer recurrence
Decaestecker, K., De Meerleer, G., Lambert, B., Delrue, L., Fonteyne, V., Claeys, T., De Vos, F., Huysse, W., Hautekiet, A., Maes, G., et al. (2014) · Radiation Oncology · doi:10.1186/1748-717x-9-135 · Cited by 255
High Dose per Fraction, Hypofractionated Treatment Effects in the Clinic (HyTEC): an overview
Grimm, J., Marks, L. B., Jackson, A., Kavanagh, B. D., Xue, J., & Yorke, E. (2021) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2020.10.039 · Cited by 153
Self-citationFrancolini, G., Allegra, A. G., Detti, B., Di Cataldo, V., Caini, S., Bruni, A., Ingrosso, G., D'Angelillo, R. M., Alitto, A. R., Augugliaro, M., et al. (2023) · Journal of Clinical Oncology · doi:10.1200/jco.23.00985 · Cited by 139
Metadata
- Authors
- Benedict, S. H., Yenice, K. M., Followill, D., Galvin, J. M., Hinson, W., Kavanagh, B., Keall, P., Lovelock, M., Meeks, S., Papiez, L., Purdie, T., Sadagopan, R., Schell, M. C., Salter, B., Schlesinger, D. J., Shiu, A. S., Solberg, T., Song, D. Y., Stieber, V., Timmerman, R., Tomé, W. A., Verellen, D., Wang, L., & Yin, F.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2010-07-14
- Volume
- 37
- Issue
- 8
- Pages
- 4078-4101
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2136706275
- Cited by
- 2,218
- References
- 88
- FWCI
- 45.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.