CoChat

Quantitative comparison of thermal dose models in normal canine brain

Open access
Yung, Joshua P., Shetty, Anil, Elliott, Andrew, Weinberg, Jeffrey S., McNichols, Roger J., Gowda, Ashok, Hazle, John D., Stafford, R. Jason · 2010 · Medical Physics
Cited by 59

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose: Minimally invasive thermal ablative therapies as alternatives to conventional surgical management of solid tumors and other pathologies is increasing owing to the potential benefits of performing these procedures in an outpatient setting with reduced complications and comorbidity. Magnetic resonance temperature imaging (MRTI) measurement allows existing thermal dose models to use the spatiotemporal temperature history to estimate the thermal damage to tissue. However, the various thermal dose models presented in the literature employ different parameters and thresholds, affecting the reliability of thermal dosimetry. In this study, the authors quantitatively compared three thermal dose models (Arrhenius rate process,, and threshold temperature) using the dice similarity coefficient (DSC). Methods: The DSC was used to compare the spatial overlap between the region of thermal damage as predicted by the models for in vivo normal canine brain during thermal therapy to the region of thermal damage as revealed by contrast‐enhanced T1‐weighted images acquired immediately after therapy . The outer edge of the hyperintense rim of the ablation region was used as the surrogate marker for the limits of thermal coagulation. The DSC was also used to investigate the impact of varying the thresholds on each models’ ability to predict the zone of thermal necrosis. Results: At previously reported thresholds, the authors found that all three models showed good agreement (defined as) with post‐treatment imaging. All three models examined across the range of commonly applied thresholds consistently showed highly accurate spatial overlap, low variability, and little dependence on temperature uncertainty. DSC values corresponding to cited thresholds were not significantly different from peak DSC values. Conclusions: Thus, the authors conclude that the all three thermal dose models can be used as a reliable surrogate for postcontrast tissue damage verification imaging in rapid ablation procedures and can also be used to enhance the capability of MRTI to control thermal therapy in real time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3490085

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Yung, J. P., Shetty, A., Elliott, A., Weinberg, J. S., McNichols, R. J., Gowda, A., Hazle, J. D., & Stafford, R. J.
Venue
Medical Physics
Publisher
Wiley
Published
2010-09-20
Volume
37
Issue
10
Pages
5313-5321
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2043617650
Cited by
59
References
2
FWCI
2.18
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.