Photoacoustic angiography of the breast

Open access
Kruger, Robert A., Lam, Richard B., Reinecke, Daniel R., Del Rio, Stephen P., Doyle, Ryan P. · 2010 · Medical Physics

Abstract

Purpose: The authors report a noninvasive technique and instrumentation for visualizing vasculature in the breast in three dimensions without using either ionizing radiation or exogenous contrast agents, such as iodine or gadolinium. Vasculature is visualized by virtue of its high hemoglobin content compared to surrounding breast parenchyma. The technique is compatible with dynamic contrast‐enhanced studies. Methods: Photoacoustic sonic waves were stimulated in the breast with a pulsed laser operating at 800 nm and a mean exposure of 20 mJ/pulse over an area of. These waves were subsequently detected by a hemispherical array of piezoelectric transducers, the temporal signals from which were filtered and backprojected to form three‐dimensional images with nearly uniform k‐space sampling. Results: Three‐dimensional vascular images of a human volunteer demonstrated a clear visualization of vascular anatomy with submillimeter spatial resolution to a maximum depth of 40 mm using a 24 s image acquisition protocol. Spatial resolution was nearly isotropic and approached over a field of view. Conclusions: The authors have successfully visualized submillimeter breast vasculature to a depth of 40 mm using an illumination intensity that is 32 times less than the maximum permissible exposure according to the American National Standard for Safe Use of Lasers. Clearly, the authors can achieve greater penetration depth in the breast by increasing the intensity and the cross‐sectional area of the illumination beam. Given the 24 s image acquisition time without contrast agent, dynamic, contrast‐enhanced, photoacoustic breast imaging using optically absorbing contrast agents is conceivable in the future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3497677

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

Metadata

Authors
Kruger, R. A., Lam, R. B., Reinecke, D. R., Del Rio, S. P., & Doyle, R. P.
Venue
Medical Physics
Publisher
Wiley
Published
2010-11
Volume
37
Issue
11
Pages
6096-6100
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2149015921
Cited by
302
References
19
FWCI
13.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.