The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Photoacoustic angiography of the breast
Open accessAbstract
Purpose: The authors report a noninvasive technique and instrumentation for visualizing vasculature in the breast in three dimensions without using either ionizing radiation or exogenous contrast agents, such as iodine or gadolinium. Vasculature is visualized by virtue of its high hemoglobin content compared to surrounding breast parenchyma. The technique is compatible with dynamic contrast‐enhanced studies. Methods: Photoacoustic sonic waves were stimulated in the breast with a pulsed laser operating at 800 nm and a mean exposure of 20 mJ/pulse over an area of. These waves were subsequently detected by a hemispherical array of piezoelectric transducers, the temporal signals from which were filtered and backprojected to form three‐dimensional images with nearly uniform k‐space sampling. Results: Three‐dimensional vascular images of a human volunteer demonstrated a clear visualization of vascular anatomy with submillimeter spatial resolution to a maximum depth of 40 mm using a 24 s image acquisition protocol. Spatial resolution was nearly isotropic and approached over a field of view. Conclusions: The authors have successfully visualized submillimeter breast vasculature to a depth of 40 mm using an illumination intensity that is 32 times less than the maximum permissible exposure according to the American National Standard for Safe Use of Lasers. Clearly, the authors can achieve greater penetration depth in the breast by increasing the intensity and the cross‐sectional area of the illumination beam. Given the 24 s image acquisition time without contrast agent, dynamic, contrast‐enhanced, photoacoustic breast imaging using optically absorbing contrast agents is conceivable in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1968) · American Association of Industrial Nurses Journal · doi:10.1177/216507996801601208 · Cited by 8,798
American Cancer Society Guidelines for Breast Screening with MRI as an Adjunct to Mammography
Saslow, D., Boetes, C., Burke, W., Harms, S., Leach, M. O., Lehman, C. D., Morris, E., Pisano, E., Schnall, M., Sener, S., et al. (2007) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.57.2.75 · Cited by 2,637
Berg, W. A., Gutierrez, L., NessAiver, M. S., Carter, W. B., Bhargavan, M., Lewis, R. S., & Ioffe, O. B. (2004) · Radiology · doi:10.1148/radiol.2333031484 · Cited by 1,439
Carney, P. A., Miglioretti, D. L., Yankaskas, B. C., Kerlikowske, K., Rosenberg, R., Rutter, C. M., Geller, B. M., Abraham, L. A., Taplin, S. H., Dignan, M., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-3-200302040-00008 · Cited by 1,142
INDOCYANINE GREEN: OBSERVATIONS ON ITS PHYSICAL PROPERTIES, PLASMA DECAY, AND HEPATIC EXTRACTION*
Cherrick, G. R., Stein, S. W., Leevy, C. M., & Davidson, C. S. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104072 · Cited by 979
Wray, S., Cope, M., Delpy, D. T., Wyatt, J. S., & Reynolds, E. O. R. (1988) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(88)90069-2 · Cited by 912
Photoacoustic ultrasound (PAUS)—Reconstruction tomography
Kruger, R. A., Liu, P., Fang, Y. “., & Appledorn, C. R. (1995) · Medical Physics · doi:10.1118/1.597429 · Cited by 572
Self-citationLaser optoacoustic imaging system for detection of breast cancer
Ermilov, S. A., Khamapirad, T., Conjusteau, A., Leonard, M. H., Lacewell, R., Mehta, K., Miller, T., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3086616 · Cited by 493
Cerussi, A., Shah, N., Hsiang, D., Durkin, A., Butler, J., & Tromberg, B. J. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2337546 · Cited by 421
Rosenberg, R. D., Hunt, W. C., Williamson, M. R., Gilliland, F. D., Wiest, P. W., Kelsey, C. A., Key, C. R., & Linver, M. N. (1998) · Radiology · doi:10.1148/radiology.209.2.9807581 · Cited by 364
Assessing the future of diffuse optical imaging technologies for breast cancer management
Tromberg, B. J., Pogue, B. W., Paulsen, K. D., Yodh, A. G., Boas, D. A., & Cerussi, A. E. (2008) · Medical Physics · doi:10.1118/1.2919078 · Cited by 326
Thermoacoustic Molecular Imaging of Small Animals
Kruger, R. A., Kiser, W. L., Reinecke, D. R., Kruger, G. A., & Miller, K. D. (2003) · Molecular Imaging · doi:10.1162/15353500200303109 · Cited by 187
Self-citationKerlikowske, K. M. (1996) · JAMA · doi:10.1001/jama.276.1.39 · Cited by 164
Photoacoustic imaging with deconvolution algorithm
Wang, Y., Xing, D., Zeng, Y., & Chen, Q. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/006 · Cited by 154
Contrast-enhanced digital mammography
Dromain, C., Balleyguier, C., Adler, G., Garbay, J. R., & Delaloge, S. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.07.035 · Cited by 149
Brix, G., Griebel, J., Kiessling, F. M., & Wenz, F. K. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1448-7 · Cited by 110
Likelihood Ratios for Modern Screening Mammography
Kerlikowske, K. M. (1996) · JAMA · doi:10.1001/jama.1996.03540010041028 · Cited by 109
Pifferi, A., Swartling, J., Chikoidze, E., Torricelli, A. M., Taroni, P., Bassi, A. L., Andersson‐Engels, S., & Cubeddu, R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1802171 · Cited by 96
Dynamic Contrast-Enhanced Breast MR Imaging
Moon, M., Cornfeld, D., & Weinreb, J. C. (2009) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2009.01.010 · Cited by 74
Cited by
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
A practical guide to photoacoustic tomography in the life sciences
Wang, L. V., & Yao, J. (2016) · Nature Methods · doi:10.1038/nmeth.3925 · Cited by 1,394
Yao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Advances in real-time multispectral optoacoustic imaging and its applications
Taruttis, A., & Ntziachristos, V. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.29 · Cited by 594
Metadata
- Authors
- Kruger, R. A., Lam, R. B., Reinecke, D. R., Del Rio, S. P., & Doyle, R. P.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2010-11
- Volume
- 37
- Issue
- 11
- Pages
- 6096-6100
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2149015921
- Cited by
- 302
- References
- 19
- FWCI
- 13.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.