The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Low-dose computed tomography image restoration using previous normal-dose scan: Low-dose CT image restoration using previous normal-dose scan
Open accessAbstract
PURPOSE: In current computed tomography (CT) examinations, the associated x-ray radiation dose is of a significant concern to patients and operators. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) or kVp parameter (or delivering less x-ray energy to the body) as low as reasonably achievable in data acquisition. However, lowering the mAs parameter will unavoidably increase data noise and the noise would propagate into the CT image if no adequate noise control is applied during image reconstruction. Since a normal-dose high diagnostic CT image scanned previously may be available in some clinical applications, such as CT perfusion imaging and CT angiography (CTA), this paper presents an innovative way to utilize the normal-dose scan as a priori information to induce signal restoration of the current low-dose CT image series. METHODS: Unlike conventional local operations on neighboring image voxels, nonlocal means (NLM) algorithm utilizes the redundancy of information across the whole image. This paper adapts the NLM to utilize the redundancy of information in the previous normal-dose scan and further exploits ways to optimize the nonlocal weights for low-dose image restoration in the NLM framework. The resulting algorithm is called the previous normal-dose scan induced nonlocal means (ndiNLM). Because of the optimized nature of nonlocal weights calculation, the ndiNLM algorithm does not depend heavily on image registration between the current low-dose and the previous normal-dose CT scans. Furthermore, the smoothing parameter involved in the ndiNLM algorithm can be adaptively estimated based on the image noise relationship between the current low-dose and the previous normal-dose scanning protocols. RESULTS: Qualitative and quantitative evaluations were carried out on a physical phantom as well as clinical abdominal and brain perfusion CT scans in terms of accuracy and resolution properties. The gain by the use of the previous normal-dose scan via the presented ndiNLM algorithm is noticeable as compared to a similar approach without using the previous normal-dose scan. CONCLUSIONS: For low-dose CT image restoration, the presented ndiNLM method is robust in preserving the spatial resolution and identifying the low-contrast structure. The authors can draw the conclusion that the presented ndiNLM algorithm may be useful for some clinical applications such as in perfusion imaging, radiotherapy, tumor surveillance, etc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Non-Local Algorithm for Image Denoising
Buades, A., Coll, B., & Morel, J.-M. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.38 · Cited by 7,616
Denoising of Dynamic Contrast-Enhanced MR Images Using Dynamic Nonlocal Means
Gal, Y., Mehnert, A. J. H., Bradley, A. P., McMahon, K., Kennedy, D., & Crozier, S. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2026575 · Cited by 78
Cited by
Yang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
aLow-dose CT via convolutional neural network
Chen, H., Zhang, Y., Zhang, W., Liao, P., Li, K., Zhou, J., & Wang, G. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000679 · Cited by 755
Sharpness-Aware Low-Dose CT Denoising Using Conditional Generative Adversarial Network
Yi, X., & Babyn, P. (2018) · Journal of Digital Imaging · doi:10.1007/s10278-018-0056-0 · Cited by 343
Liu, Y., Ma, J., Fan, Y., & Liang, Z. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7923 · Cited by 335
Self-citationLi, M., Hsu, W., Xie, X., Cong, J., & Gao, W. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2968472 · Cited by 321
Metadata
- Authors
- Ma, J., Huang, J., Feng, Q., Zhang, H., Lu, H., Liang, Z., & Chen, W.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2011-09-26
- Volume
- 38
- Issue
- 10
- Pages
- 5713-5731
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2037511378
- Cited by
- 249
- References
- 2
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-dose computed tomography image restoration using previous normal-dose scan: Low-dose CT image restoration using previous normal-dose scan. https://app.cochat.ai/papers/10.1118/1.3638125
- The paper
- Ma, J., Huang, J., Feng, Q., Zhang, H., Lu, H., Liang, Z., & Chen, W. (2011). Low-dose computed tomography image restoration using previous normal-dose scan: Low-dose CT image restoration using previous normal-dose scan. Medical Physics. https://doi.org/10.1118/1.3638125
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.