Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 277

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

A PENELOPE‐based system for the automated Monte Carlo simulation of clinacs and voxelized geometries—application to far‐from‐axis fields

Open access
Sempau, Josep, Badal, Andreu, Brualla, Lorenzo·2011·Medical Physics

Abstract

Purpose: Two new codes,PEN E ASY and PEN E ASY L INAC, which automate the Monte Carlo simulation of Varian Clinacs of the 600, 1800, 2100, and 2300 series, together with their electron applicators and multileaf collimators, are introduced. The challenging case of a relatively small and far‐from‐axis field has been studied with these tools. Methods: PEN E ASY is a modular, general‐purpose main program for the PENELOPE Monte Carlo system that includes various source models, tallies and variance‐reduction techniques (VRT). The code includes a new geometry model that allows the superposition of voxels and objects limited by quadric surfaces. A variant of the VRT known as particle splitting, called fan splitting, is also introduced.PEN E ASYLINAC, in turn, automatically generates detailed geometry and configuration files to simulate linacs with PEN E ASY. These tools are applied to the generation of phase‐space files, and of the corresponding absorbed dose distributions in water, for two 6 MV photon beams from a Varian Clinac 2100 C/D: a 40 × 40 cm 2 centered field; and a 3 × 5 cm 2 field centered at (4.5, −11.5) cm from the beam central axis. This latter configuration implies the largest possible over‐traveling values of two of the jaws. Simulation results for the depth dose and lateral profiles at various depths are compared, by using the gamma index, with experimental values obtained with a PTW 31002 ionization chamber. The contribution of several VRTs to the computing speed of the more demanding off‐axis case is analyzed. Results: For the 40 × 40 cm 2 field, the percentages γ 1 and γ 1.2 of voxels with gamma indices (using 0.2 cm and 2% criteria) larger than unity and larger than 1.2 are 0.2% and 0%, respectively. For the 3 × 5 cm 2 field, γ 1 = 0%. These figures indicate an excellent agreement between simulation and experiment. The dose distribution for the off‐axis case with voxels of 2.5 × 2.5 × 2.5 mm 3 and an average standard statistical uncertainty of 2% (1σ) is computed in 3.1 h on a single core of a 2.8 GHz Intel Core 2 Duo processor. This result is obtained with the optimal combination of the tested VRTs. In particular, fan splitting for the off‐axis case accelerates execution by a factor of 240 with respect to standard particle splitting. Conclusions: PEN E ASY and PEN E ASY L INAC can simulate the considered Varian Clinacs both in an accurate and efficient manner. Fan splitting is crucial to achieve simulation results for the off‐axis field in an affordable amount of CPU time. Work to include Elekta linacs and to develop a graphical interface that will facilitate user input is underway.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3643029

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 277

Metadata

Authors
Sempau, J., Badal, A., & Brualla, L.
Venue
Medical Physics
Publisher
Wiley
Published
2011-10-11
Volume
38
Issue
11
Pages
5887-5895
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2064257567
Cited by
277
References
14
FWCI
14.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A PENELOPE‐based system for the automated Monte Carlo simulation of clinacs and voxelized geometries—application to far‐from‐axis fields. https://app.cochat.ai/papers/10.1118/1.3643029
The paper
Sempau, J., Badal, A., & Brualla, L. (2011). A PENELOPE‐based system for the automated Monte Carlo simulation of clinacs and voxelized geometries—application to far‐from‐axis fields. Medical Physics. https://doi.org/10.1118/1.3643029

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.