Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 568

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

National survey of doses from CT in the UK: 2003

Shrimpton, P C, Hillier, M C, Lewis, M A, Dunn, M·2006·The British Journal of Radiology

Abstract

A review of patient doses from CT examinations in the UK for 2003 has been conducted on the basis of data received from over a quarter of all UK scanners, of which 37% had multislice capability. Questionnaires were employed to collect scan details both for the standard protocols established at each scanner for 12 common types of CT examination on adults and children, and for samples of individual patients. This information was combined with published scanner-specific CT dose index (CTDI) coefficients to estimate values of the standard dose indices CTDI(w) and CTDI(vol) for each scan sequence. Knowledge of each scan length allowed assessment of the dose-length product (DLP) for each examination, from which effective doses were then estimated. When compared with a previous UK survey for 1991, wide variations were still apparent between CT centres in the doses for standard protocols. The mean UK doses for adult patients were in general lower by up to 50% than those for 1991, although doses were slightly higher for multislice (4+) (MSCT) relative to single slice (SSCT) scanners. Values of CTDI(vol) for MSCT were broadly similar to European survey data for 2001. The third quartile values of these dose distributions have been used to derive UK national reference doses for examinations on adults (separately for SSCT and MSCT) and children as initial tools for promoting patient protection. The survey has established the PREDICT (Patient Radiation Exposure and Dose in CT) database as a sustainable national resource for monitoring dose trends in CT through the ongoing collation of further survey data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1259/bjr/93277434

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 568

Metadata

Authors
Shrimpton, P. C., Hillier, M. C., Lewis, M. A., & Dunn, M.
Venue
The British Journal of Radiology
Published
2006-12
Volume
79
Issue
948
Pages
968-980
ISSN
  • 0007-1285 (ISSN-L)
  • 1748-880X
OpenAlex
W2074719332
Cited by
568
References
18
FWCI
10.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: National survey of doses from CT in the UK: 2003. https://app.cochat.ai/papers/10.1259/bjr/93277434
The paper
Shrimpton, P. C., Hillier, M. C., Lewis, M. A., & Dunn, M. (2006). National survey of doses from CT in the UK: 2003. The British Journal of Radiology. https://doi.org/10.1259/bjr/93277434

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.