The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
TOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Open accessAbstract
Purpose: While Monte Carlo particle transport has proven useful in many areas (treatment head design, dose calculation, shielding design, and imaging studies) and has been particularly important for proton therapy (due to the conformal dose distributions and a finite beam range in the patient), the available general purpose Monte Carlo codes in proton therapy have been overly complex for most clinical medical physicists. The learning process has large costs not only in time but also in reliability. To address this issue, we developed an innovative proton Monte Carlo platform and tested the tool in a variety of proton therapy applications. Methods: Our approach was to take one of the already‐established general purpose Monte Carlo codes and wrap and extend it to create a specialized user‐friendly tool for proton therapy. The resulting tool, TOol for PArticle Simulation (TOPAS), should make Monte Carlo simulation more readily available for research and clinical physicists. TOPAS can model a passive scattering or scanning beam treatment head, model a patient geometry based on computed tomography (CT) images, score dose, fluence, etc., save and restart a phase space, provides advanced graphics, and is fully four‐dimensional (4D) to handle variations in beam delivery and patient geometry during treatment. A custom‐designed TOPAS parameter control system was placed at the heart of the code to meet requirements for ease of use, reliability, and repeatability without sacrificing flexibility. Results: We built and tested the TOPAS code. We have shown that the TOPAS parameter system provides easy yet flexible control over all key simulation areas such as geometry setup, particle source setup, scoring setup, etc. Through design consistency, we have insured that user experience gained in configuring one component, scorer or filter applies equally well to configuring any other component, scorer or filter. We have incorporated key lessons from safety management, proactively removing possible sources of user error such as line‐ordering mistakes. We have modeled proton therapy treatment examples including the UCSF eye treatment head, the MGH stereotactic alignment in radiosurgery treatment head and the MGH gantry treatment heads in passive scattering and scanning modes, and we have demonstrated dose calculation based on patient‐specific CT data. Initial validation results show agreement with measured data and demonstrate the capabilities of TOPAS in simulating beam delivery in 3D and 4D. Conclusions: We have demonstrated TOPAS accuracy and usability in a variety of proton therapy setups. As we are preparing to make this tool freely available for researchers in medical physics, we anticipate widespread use of this tool in the growing proton therapy community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Self-citationGeant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946
Self-citationROOT — An object oriented data analysis framework
Brun, R., & Rademakers, F. (1997) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(97)00048-x · Cited by 4,919
FLUKA: A Multi-Particle Transport Code
Ferrari, A., Sala, P. R., Fasso, A., & Ranft, J. (2005) · doi:10.2172/877507 · Cited by 2,536
BEAM: A Monte Carlo code to simulate radiotherapy treatment units
Rogers, D. W. O., Faddegon, B. A., Ding, G. X., Ma, C. ‐., We, J., & Mackie, T. R. (1995) · Medical Physics · doi:10.1118/1.597552 · Cited by 1,431
Self-citationRange uncertainties in proton therapy and the role of Monte Carlo simulations
Paganetti, H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/11/r99 · Cited by 1,325
Self-citationKawrakow, I. (2000) · Medical Physics · doi:10.1118/1.598917 · Cited by 945
Comments on ICRU Report No. 49: Stopping Powers and Ranges for Protons and Alpha Particles
Ziegler, J. F. (1999) · Radiation Research · doi:10.2307/3580097 · Cited by 616
Janni, J. (1982) · Atomic Data and Nuclear Data Tables · doi:10.1016/0092-640x(82)90004-3 · Cited by 488
Multiple Scattering in an Infinite Medium
Lewis, H. W. (1950) · Physical Review · doi:10.1103/physrev.78.526 · Cited by 472
Instrumentation for treatment of cancer using proton and light-ion beams
Chu, W. T., Ludewigt, B. A., & Renner, T. R. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143946 · Cited by 313
Physics Settings for Using the Geant4 Toolkit in Proton Therapy
Zacharatou Jarlskog, C., & Paganetti, H. (2008) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2008.922816 · Cited by 216
Self-citationEnergy loss of 70 MeV protons in elements
Bischel, H., & Hiraoka, T. (1992) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(92)95995-4 · Cited by 89
Assessment of out‐of‐field absorbed dose and equivalent dose in proton fields
Clasie, B., Wroe, A. J., Kooy, H. M., Depauw, N., Flanz, J., Paganetti, H., & Rosenfeld, A. B. (2009) · Medical Physics · doi:10.1118/1.3271390 · Cited by 82
Self-citationEfficient voxel navigation for proton therapy dose calculation in TOPAS and Geant4
Schuemann, J., Paganetti, H., Shin, J., Faddegon, B., & Perl, J. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/11/3281 · Cited by 52
Self-citationThe Geant4 Visualisation System
Allison, J., Asai, M., Barrand, G., Dönszelmann, M., Minamimoto, K., Perl, J., Tanaka, S., Tcherniaev, E., & Tinslay, J. (2007) · Computer Physics Communications · doi:10.1016/j.cpc.2007.09.010 · Cited by 22
Self-citationBednarz, B. P., Lu, H., Engelsman, M., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/9/013 · Cited by 22
Jarlskog, C. Z., & Paganetti, H. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/004 · Cited by 22
Self-citation
Cited by
Allison, J., Amako, K., Apostolakis, J., Arce, P., Asai, M., Aso, T., Bagli, E., Bagulya, A., Banerjee, S., Barrand, G., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2016.06.125 · Cited by 4,194
Self-citationRange uncertainties in proton therapy and the role of Monte Carlo simulations
Paganetti, H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/11/r99 · Cited by 1,325
Self-citationNewhauser, W. D., & Zhang, R. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/r155 · Cited by 675
Sarrut, D., Bardiès, M., Boussion, N., Freud, N., Jan, S., Létang, J.-M., Loudos, G., Maigne, L., Marcatili, S., Mauxion, T., et al. (2014) · Medical Physics · doi:10.1118/1.4871617 · Cited by 573
Bernal, M. A., Bordage, M. C., Brown, J. M. C., Davídková, M., Delage, E., El Bitar, Z., Enger, S. A., Francis, Z., Guatelli, S., Ivanchenko, V. N., et al. (2015) · Physica Medica · doi:10.1016/j.ejmp.2015.10.087 · Cited by 536
Metadata
- Authors
- Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2012-10-19
- Volume
- 39
- Issue
- 11
- Pages
- 6818-6837
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2030544564
- Cited by
- 1,140
- References
- 18
- FWCI
- 19.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.