The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications: GATE for dosimetry
Open accessAbstract
In this paper, the authors' review the applicability of the open-source GATE Monte Carlo simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry applications. The many applications of GATE for state-of-the-art radiotherapy simulations are described including external beam radiotherapy, brachytherapy, intraoperative radiotherapy, hadrontherapy, molecular radiotherapy, and in vivo dose monitoring. Investigations that have been performed using GEANT4 only are also mentioned to illustrate the potential of GATE. The very practical feature of GATE making it easy to model both a treatment and an imaging acquisition within the same framework is emphasized. The computational times associated with several applications are provided to illustrate the practical feasibility of the simulations using current computing facilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Geant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946
FLUKA: A Multi-Particle Transport Code
Ferrari, A., Sala, P. R., Fasso, A., & Ranft, J. (2005) · doi:10.2172/877507 · Cited by 2,536
Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
Rivard, M. J., Coursey, B. M., DeWerd, L. A., Hanson, W. F., Huq, M. S., Ibbott, G. S., Mitch, M. G., Nath, R., & Williamson, J. F. (2004) · Medical Physics · doi:10.1118/1.1646040 · Cited by 1,751
The FLUKA code: description and benchmarking
Battistoni, G., Cerutti, F., Fassò, A., Ferrari, A., Muraro, S., Ranft, J., Roesler, S., & Sala, P. R. (2007) · AIP Conference Proceedings · doi:10.1063/1.2720455 · Cited by 1,308
TOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H. (2012) · Medical Physics · doi:10.1118/1.4758060 · Cited by 1,140
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Schneider, W., Bortfeld, T., & Schlegel, W. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/314 · Cited by 831
Jan, S., Benoit, D., Becheva, E., Carlier, T., Cassol, F., Descourt, P., Frisson, T., Grevillot, L., Guigues, L., Maigne, L., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/001 · Cited by 794
Self-citationWs, S., Hl, F., Mr, F., & Warner, G. G. (1969) · PubMed · Cited by 627
MIRD primer for absorbed dose calculations
LOEVINGER, R., Budinger, T. F., & Watson, E. E. (1988) · Medical Entomology and Zoology · Cited by 552
A Monte Carlo program for the simulation of scintillation camera characteristics
Ljungberg, M., & Strand, S.-E. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90111-9 · Cited by 515
Comparison of GEANT4 very low energy cross section models with experimental data in water
Incerti, S., Ivanchenko, A., Karamitros, M., Mantero, A., Moretto, P., Tran, H. N., Mascialino, B., Champion, C., Ivanchenko, V. N., Bernal, M. A., et al. (2010) · Medical Physics · doi:10.1118/1.3476457 · Cited by 514
Development of a 4-D digital mouse phantom for molecular imaging research
SEGARS, W. (2004) · Molecular Imaging & Biology · doi:10.1016/j.mibio.2004.03.002 · Cited by 420
Treatment planning for a scanned carbon beam with a modified microdosimetric kinetic model
Inaniwa, T., Furukawa, T., Kase, Y., Matsufuji, N., Toshito, T., Matsumoto, Y., Furusawa, Y., & Noda, K. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/008 · Cited by 328
Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy
Böhlen, T. T., Cerutti, F., Dosanjh, M., Ferrari, A., Gudowska, I., Mairani, A., & Quesada, J. M. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/19/014 · Cited by 162
An efficient Monte Carlo-based algorithm for scatter correction in keV cone-beam CT
Poludniowski, G. G., Evans, P., Hansen, V. N., & Webb, S. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/12/016 · Cited by 156
Bom, V. R., Joulaeizadeh, L., & Beekman, F. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/2/297 · Cited by 136
Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4
Grevillot, L., Frisson, T., Maneval, D. C., Zahra, N., Badel, J., & Sarrut, D. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/002 · Cited by 132
Self-citationPapadimitroulas, P., Loudos, G. K., Nikiforidis, G. C., & Kagadis, G. C. (2012) · Medical Physics · doi:10.1118/1.4737096 · Cited by 115
Self-citationGeant4-based Monte Carlo simulations on GPU for medical applications
Bert, J., Pérez-Ponce, H., Bitar, Z. E., Jan, S., Boursier, Y., Vintache, D., Bonissent, A., Morel, C., Brasse, D., & Visvikis, D. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/5593 · Cited by 106
Self-citationSpectroscopic characterization of a novel electronic brachytherapy system
Liu, D., Poon, E., Bazalova‐Carter, M., Reniers, B., Evans, M. D., Rusch, T. W., & Verhaegen, F. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/1/004 · Cited by 102
Interaction vertex imaging (IVI) for carbon ion therapy monitoring: a feasibility study
Henriquet, P., Testa, É., Chevallier, M., Dauvergne, D., Dedes, G., Freud, N., Krimmer, J., Létang, J. M., Ray, C., Richard, M.-H., et al. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/14/4655 · Cited by 99
Self-citationPaganetti, H., Jiang, H., Adams, J., Chen, G. T. Y., & Rietzel, E. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(04)01081-8 · Cited by 88
Maigne, L., Perrot, Y., Schaart, D. R., Donnarieix, D., & Breton, V. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/3/017 · Cited by 84
Self-citationBotta, F., Mairani, A., Battistoni, G., Cremonesi, M., Dia, A. D., Fasso, A., Ferrari, A., Ferrari, M. E., Paganelli, G., Pedroli, G., et al. (2011) · Medical Physics · doi:10.1118/1.3586038 · Cited by 80
Improved point kernels for electron and beta-ray dosimetry
Berger, M. J. (1973) · doi:10.6028/nbs.ir.73-107 · Cited by 79
Grevillot, L., Bertrand, D., Dessy, F., Freud, N., & Sarrut, D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/13/4223 · Cited by 75
Self-citationMachine learning-based patient specific prompt-gamma dose monitoring in proton therapy
Gueth, P., Dauvergne, D., Freud, N., Létang, J. M., Ray, C. D., Testa, É., & Sarrut, D. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/13/4563 · Cited by 66
Self-citationInteraction vertex imaging (IVI) for carbon ion therapy monitoring: a feasibility study
Testa, É., Dauvergne, D., Dedes, G., Freud, N., Henriquet, P., Krimmer, J., Létang, J. M., Ray, C. D., Richard, M. H., & Sauli, F. (2012) · HAL · Cited by 64
Self-citationDesign study of anin situPET scanner for use in proton beam therapy
Surti, S., Zou, W., Daube-Witherspoon, M. E., McDonough, J. E., & Karp, J. S. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/9/002 · Cited by 63
Villagrasa, C., Francis, Z., & Incerti, S. (2010) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncq537 · Cited by 62
OEDIPE: A Personalized Dosimetric Tool Associating Voxel-Based Models with MCNPX
Chiavassa, S., Bardiès, M., Guiraud-Vitaux, F., Bruel, D., Jourdain, J.-R., Franck, D., & Aubineau-Lanièce, I. (2005) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/cbr.2005.20.325 · Cited by 50
Self-citationAssessment of MIRD data for internal dosimetry using the GATE Monte Carlo code
Parach, A. A., Rajabi, H., & Askari, M. A. (2011) · Radiation and Environmental Biophysics · doi:10.1007/s00411-011-0370-0 · Cited by 44
Thijssen, L., Schaart, D. R., de Vries, D., Morgenstern, A., Bruchertseifer, F., & Denkova, A. G. (2012) · Radiochimica Acta · doi:10.1524/ract.2012.1935 · Cited by 31
Self-citationChouin, N., Bernardeau, K., Davodeau, F., Chérel, M., Faivre-Chauvet, A., Bourgeois, M., Apostolidis, C., Morgenstern, A., Lisbona, A., & Bardiès, M. (2009) · Radiation Research · doi:10.1667/rr1371.1 · Cited by 29
Self-citationChofor, N., Harder, D., Willborn, K., Rühmann, A., & Poppe, B. (2011) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2011.02.002 · Cited by 28
Validation of a small-animal PET simulation using GAMOS: a GEANT4-based framework
Cañadas, M., Arce, P. E., & Mendes, P. R. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/016 · Cited by 26
3D calculation of absorbed dose for 131I-targeted radiotherapy: a Monte Carlo study
Saeedzadeh, E., Sarkar, S., Tehrani‐Fard, A. A., Ay, M. R., Khosravi, H., & Loudos, G. K. (2011) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr411 · Cited by 22
Self-citationHadrontherapy: An open source, Geant4-based application for proton-ion therapy studies
Cirrone, G. A. P., Cuttone, G., Rosa, F. D., et al. (2009) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2009.5402279 · Cited by 18
Cited by
Green Algorithms: Quantifying the Carbon Footprint of Computation
Lannelongue, L., Grealey, J., & Inouye, M. (2021) · Advanced Science · doi:10.1002/advs.202100707 · Cited by 543
Role of Artificial Intelligence in Theranostics
Brosch-Lenz, J., Yousefirizi, F., Zukotynski, K., Beauregard, J.-M., Gaudet, V., Saboury, B., Rahmim, A., & Uribe, C. (2021) · PET Clinics · doi:10.1016/j.cpet.2021.06.002 · Cited by 42
Sangwan, N., & Kumar, A. (2022) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2021.110068 · Cited by 4
Metadata
- Authors
- Sarrut, D., Bardiès, M., Boussion, N., Freud, N., Jan, S., Létang, J.-M., Loudos, G., Maigne, L., Marcatili, S., Mauxion, T., Papadimitroulas, P., Perrot, Y., Pietrzyk, U., Robert, C., Schaart, D. R., Visvikis, D., & Buvat, I.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2014-05-12
- Volume
- 41
- Issue
- 6Part1
- Pages
- 064301
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2002849978
- Cited by
- 573
- References
- 40
- FWCI
- 26.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.