The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
The ANACONDA algorithm for deformable image registration in radiotherapy
Abstract
Purpose: The purpose of this work was to describe a versatile algorithm for deformable image registration with applications in radiotherapy and to validate it on thoracic 4DCT data as well as CT/cone beam CT (CBCT) data. Methods: ANAtomically CONstrained Deformation Algorithm (ANACONDA) combines image information (i.e., intensities) with anatomical information as provided by contoured image sets. The registration problem is formulated as a nonlinear optimization problem and solved with an in‐house developed solver, tailored to this problem. The objective function, which is minimized during optimization, is a linear combination of four nonlinear terms: 1. image similarity term; 2. grid regularization term, which aims at keeping the deformed image grid smooth and invertible; 3. a shape based regularization term which works to keep the deformation anatomically reasonable when regions of interest are present in the reference image; and 4. a penalty term which is added to the optimization problem when controlling structures are used, aimed at deforming the selected structure in the reference image to the corresponding structure in the target image. Results: To validate ANACONDA, the authors have used 16 publically available thoracic 4DCT data sets for which target registration errors from several algorithms have been reported in the literature. On average for the 16 data sets, the target registration error is 1.17 ± 0.87 mm, Dice similarity coefficient is 0.98 for the two lungs, and image similarity, measured by the correlation coefficient, is 0.95. The authors have also validated ANACONDA using two pelvic cases and one head and neck case with planning CT and daily acquired CBCT. Each image has been contoured by a physician (radiation oncologist) or experienced radiation therapist. The results are an improvement with respect to rigid registration. However, for the head and neck case, the sample set is too small to show statistical significance. Conclusions: ANACONDA performs well in comparison with other algorithms. By including CT/CBCT data in the validation, the various aspects of the algorithm such as its ability to handle different modalities, large deformations, and air pockets are shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lecture Notes in Computer Science 1205
(1999) · Industrial Robot: An International Journal · doi:10.1108/ir.1999.04926fae.001 · Cited by 38,662
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874
Proceedings of the 19th International Joint Conference on Artificial Intelligence
Pujol, J. M., Delgado, J., Ramon Sangüesa, A., & Flache, A. (2005) · International Joint Conference on Artificial Intelligence · Cited by 5,771
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
Representations of quasi-Newton matrices and their use in limited memory methods
Byrd, R. H., Nocedal, J., & Schnabel, R. B. (1994) · Mathematical Programming · doi:10.1007/bf01582063 · Cited by 744
Non-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707
Castillo, R., Castillo, E., Guerra, R., Johnson, V. E., McPhail, T., Garg, A. K., & Guerrero, T. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/7/001 · Cited by 592
Rohlfing, T. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2163944 · Cited by 412
DRAMMS: Deformable registration via attribute matching and mutual-saliency weighting
Ou, Y., Sotiras, A., Paragios, N., & Davatzikos, C. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.07.002 · Cited by 407
Accuracy of finite element model‐based multi‐organ deformable image registration
Brock, K. K., Sharpe, M. B., Dawson, L. A., Kim, S. M., & Jaffray, D. A. (2005) · Medical Physics · doi:10.1118/1.1915012 · Cited by 375
Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)
Brock, K. K. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.06.031 · Cited by 358
Intensity-Based Image Registration by Minimizing Residual Complexity
Myronenko, A., & Song, X. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053043 · Cited by 325
Four-dimensional deformable image registration using trajectory modeling
Castillo, E., Castillo, R., Martinez, J., Shenoy, M., & Guerrero, T. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/018 · Cited by 261
Castadot, P., Lee, J. A., Parraga, A., Geets, X., Macq, B., & Grégoire, V. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2008.04.010 · Cited by 198
Deformable Medical Image Registration: Setting the State of the Art with Discrete Methods
Glocker, B., Sotiras, A., Komodakis, N., & Paragios, N. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124649 · Cited by 193
Spatiotemporal motion estimation for respiratory‐correlated imaging of the lungs
Vandemeulebroucke, J., Rit, S., Kybic, J., Clarysse, P., & Sarrut, D. (2011) · Medical Physics · doi:10.1118/1.3523619 · Cited by 172
Large deformation three-dimensional image registration in image-guided radiation therapy
Foskey, M., Davis, B., Goyal, L., Chang, S., Chaney, E., Strehl, N., Tomei, S., Rosenman, J., & Joshi, S. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/24/008 · Cited by 172
Image registration and data fusion in radiation therapy
Kessler, M. L. (2006) · The British Journal of Radiology · doi:10.1259/bjr/70617164 · Cited by 165
The need for application‐based adaptation of deformable image registration
Kirby, N., Chuang, C., Ueda, U., & Pouliot, J. (2013) · Medical Physics · doi:10.1118/1.4769114 · Cited by 164
Objective assessment of deformable image registration in radiotherapy: A multi‐institution study
Kashani, R., Hub, M., Balter, J. M., Kessler, M. L., Dong, L., Zhang, L., Xing, L., Xie, Y., Hawkes, D. J., Schnabel, J. A., et al. (2008) · Medical Physics · doi:10.1118/1.3013563 · Cited by 160
Therapeutic options for recurrent malignant glioma
Niyazi, M., Siefert, A., Schwarz, S. B., Ganswindt, U., Kreth, F.-W., Tonn, J., & Belka, C. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.11.006 · Cited by 150
Analysis of deformable image registration accuracy using computational modeling
Zhong, H., Kim, J., & Chetty, I. J. (2010) · Medical Physics · doi:10.1118/1.3302141 · Cited by 122
Christensen, G. E., Carlson, B., Chao, K. S. C., Yin, P., Grigsby, P. W., Nguyen, K., Dempsey, J. F., Lerma, F. A., Bae, K. T., Vannier, M. W., et al. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01667-4 · Cited by 118
Is it sensible to “deform” dose? 3D experimental validation of dose‐warping
Yeo, A. U., Taylor, M. L., Supple, J., Smith, R. L., Dunn, L., Kron, T., & Franich, R. D. (2012) · Medical Physics · doi:10.1118/1.4736534 · Cited by 110
Deformable planning CT to cone‐beam CT image registration in head‐and‐neck cancer
Hou, J., Guerrero, M., Chen, W., & D'Souza, W. D. (2011) · Medical Physics · doi:10.1118/1.3554647 · Cited by 105
Demons deformable registration of CT and cone‐beam CT using an iterative intensity matching approach
Nithiananthan, S., Schäfer, S., Uneri, A., Mirota, D. J., Stayman, J. W., Zbijewski, W. B., Brock, K. K., Daly, M. J., Chan, H. H. L., Irish, J. C., et al. (2011) · Medical Physics · doi:10.1118/1.3555037 · Cited by 97
Risser, L., Vialard, F., Baluwala, H. Y., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.10.001 · Cited by 92
Registration of sliding objects using direction dependent B-splines decomposition
Delmon, V., Rit, S., Pinho, R., & Sarrut, D. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/5/1303 · Cited by 86
Eom, J., Xu, X. G., De, S., et al. (2010) · Medical Physics · doi:10.1118/1.3455276 · Cited by 85
Niu, T., Al-Basheer, A. K., & Zhu, L. (2012) · Medical Physics · doi:10.1118/1.3693050 · Cited by 80
Non-linear cerebral registration with sulcal constraints
Collins, D. L., Goualher, G. L., & Evans, A. C. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056286 · Cited by 73
A finite element method to correct deformable image registration errors in low-contrast regions
Zhong, H., Kim, J., Li, H., Nurushev, T. S., Movsas, B., & Chetty, I. J. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/11/3499 · Cited by 61
Pukala, J., Meeks, S. L., Staton, R. J., Bova, F. J., Manon, R. R., & Langen, K. (2013) · Medical Physics · doi:10.1118/1.4823467 · Cited by 56
Automated registration of large deformations for adaptive radiation therapy of prostate cancer
Godley, A. R., Ahunbay, E. E., Peng, C., & Li, X. A. (2009) · Medical Physics · doi:10.1118/1.3095777 · Cited by 55
Bertelsen, A. S., Schytte, T., Bentzen, S. M., Hansen, O., Nielsen, M., & Brink, C. (2011) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2011.08.012 · Cited by 53
A contour-guided deformable image registration algorithm for adaptive radiotherapy
Gu, X., Dong, B., Wang, J., Yordy, J. S., Mell, L. K., Jia, X., & Jiang, S. B. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/6/1889 · Cited by 49
Kim, J., Kumar, S. S., Liu, C., Zhong, H., Pradhan, D. R., Shah, M., Cattaneo, R., Yechieli, R. L., Robbins, J. R., Elshaikh, M. A., et al. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8077 · Cited by 43
Bernon, J. L., Boudousq, V., Rohmer, J. F., et al. (2001) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(00)00073-2 · Cited by 39
Joint CT/CBCT deformable registration and CBCT enhancement for cancer radiotherapy
Lou, Y., Niu, T., Jia, X., Vela, P. A., Zhu, L., & Tannenbaum, A. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.01.005 · Cited by 36
Metadata
- Authors
- Weistrand, O., & Svensson, S.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2015-01
- Volume
- 42
- Issue
- 1
- Pages
- 40-53
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2085956509
- Cited by
- 284
- References
- 41
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.