The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Intensity-Based Image Registration by Minimizing Residual Complexity
Abstract
Accurate definition of the similarity measure is a key component in image registration. Most commonly used intensity-based similarity measures rely on the assumptions of independence and stationarity of the intensities from pixel to pixel. Such measures cannot capture the complex interactions among the pixel intensities, and often result in less satisfactory registration performances, especially in the presence of spatially-varying intensity distortions. We propose a novel similarity measure that accounts for intensity nonstationarities and complex spatially-varying intensity distortions in mono-modal settings. We derive the similarity measure by analytically solving for the intensity correction field and its adaptive regularization. The final measure can be interpreted as one that favors a registration with minimum compression complexity of the residual image between the two registered images. One of the key advantages of the new similarity measure is its simplicity in terms of both computational complexity and implementation. This measure produces accurate registration results on both artificial and real-world problems that we have tested, and outperforms other state-of-the-art similarity measures in these cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Sparse coding with an overcomplete basis set: A strategy employed by V1?
Olshausen, B. A., & Field, D. J. (1997) · Vision Research · doi:10.1016/s0042-6989(97)00169-7 · Cited by 3,642
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“Myronenko and Song proposed to use residual complexity (RC) to account for complex spatially-varying intensity distortions [327].”
BackgroundDeep learning in medical image registration: a survey
Haskins, G., Kruger, U., & Yan, P. (2020) · Machine Vision and Applications · doi:10.1007/s00138-020-01060-x · Cited by 704
MRF-Based Deformable Registration and Ventilation Estimation of Lung CT
Heinrich, H. P., Jenkinson, M., Brady, M., & Schnabel, J. A. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2246577 · Cited by 311
Birnet: Brain image registration using dual-supervised fully convolutional networks
Fan, J., Cao, X., Yap, P.-T., & Shen, D. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.03.006 · Cited by 297
Metadata
- Authors
- Myronenko, A., & Song, X.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-11
- Volume
- 29
- Issue
- 11
- Pages
- 1882-1891
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2126511344
- Cited by
- 325
- References
- 4
- FWCI
- 16.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intensity-Based Image Registration by Minimizing Residual Complexity. https://app.cochat.ai/papers/10.1109/tmi.2010.2053043
- The paper
- Myronenko, A., & Song, X. (2010). Intensity-Based Image Registration by Minimizing Residual Complexity. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2010.2053043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.