The DOI matches its Crossref record.
Noise and filtration in magnetic resonance imaging
Open accessAbstract
Noise in two‐dimensional Fourier transform magnetic resonance images has been investigated using noise power spectra and measurements of standard deviation. The measured effects of averaging, spatial filtering, temporal filtering, and sampling have been compared with theoretical calculations. The noise of unfiltered images is found to be white, as expected, and the choice of the temporal filter and sampling interval affects the noise in a manner predicted by sampling theory. The shapes of the imager's spatial frequency filters are extracted using noise power spectra.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
Deformable templates using large deformation kinematics
Christensen, G. E., Rabbitt, R. D., & Miller, M. I. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.536892 · Cited by 1,142
Dietrich, O., Raya, J. G., Reeder, S. B., Reiser, M. F., & Schoenberg, S. O. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20969 · Cited by 992
Wavelet transform domain filters: a spatially selective noise filtration technique
Xu, Y., Weaver, J. B., Healy, D. M., & Lu, J. (1994) · IEEE Transactions on Image Processing · doi:10.1109/83.336245 · Cited by 747
MRI segmentation: Methods and applications
Clarke, L. P., Velthuizen, R. P., Camacho, M. A., Heine, J. J., Vaidyanathan, M., Hall, L. O., Thatcher, R. W., & Silbiger, M. L. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00124-l · Cited by 695
Wavelet-based Rician noise removal for magnetic resonance imaging
Nowak, R. D. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.791966 · Cited by 620
A versatile wavelet domain noise filtration technique for medical imaging
Pizurica, A., Philips, W., Lemahieu, I., & Acheroy, M. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809588 · Cited by 531
Signal‐to‐noise measurements in magnitude images from NMR phased arrays
Constantinides, C. D., Atalar, E., & McVeigh, E. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380524 · Cited by 510
Self-citationFat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise
Liu, C., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21301 · Cited by 477
Volumetric transformation of brain anatomy
Christensen, G. E., Joshi, S. C., & Miller, M. I. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650882 · Cited by 438
Fast Fluid Registration of medical images
Bro-Nielsen, M., & Gramkow, C. (1996) · Lecture Notes in Computer Science · doi:10.1007/bfb0046964 · Cited by 395
Model-Based Image Reconstruction for MRI
Fessler, J. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936726 · Cited by 335
A survey on the magnetic resonance image denoising methods
Mohan, J., Krishnaveni, V., & Guo, Y. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.10.007 · Cited by 295
Metadata
- Authors
- McVeigh, E. R., Henkelman, R. M., & Bronskill, M. J.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1985-09
- Volume
- 12
- Issue
- 5
- Pages
- 586-591
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2105672072
- Cited by
- 222
- References
- 0
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.