MR image artifacts from periodic motion
Abstract
Artifacts due to periodic motion during the acquisition of magnetic resonance (MR) images have been studied. A mechanical device was constructed to oscillate a small sample along any line within a 0.15‐T Technicare imager. Two‐ and three‐dimensional images were obtained using various frequencies and amplitudes of oscillation. Computer simulations of these experiments yielded images which agreed with the experiments. We demonstrated that movement influences MR images locally through blurring, and also generates ghost artifacts along the phase‐encoding directions of the Fourier transform imaging technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Motion artifacts in MRI: A complex problem with many partial solutions
Zaitsev, M., Maclaren, J., & Herbst, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24850 · Cited by 774
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Respiratory motion models: A review
McClelland, J. R., Hawkes, D. J., Schaeffter, T., & King, A. P. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.09.005 · Cited by 385
Radiotherapy planning using MRI
Schmidt, M. A., & Payne, G. S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/22/r323 · Cited by 357
Bernstein, M. A., Huston, J., & Ward, H. A. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20698 · Cited by 255
Metadata
- Authors
- Wood, M. L., & Henkelman, R. M.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1985-03
- Volume
- 12
- Issue
- 2
- Pages
- 143-151
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2086164033
- Cited by
- 302
- References
- 0
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MR image artifacts from periodic motion. https://app.cochat.ai/papers/10.1118/1.595782
- The paper
- Wood, M. L., & Henkelman, R. M. (1985). MR image artifacts from periodic motion. Medical Physics. https://doi.org/10.1118/1.595782
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.