Magnetic resonance imaging of stationary blood: A review
The DOI matches its Crossref record.
Abstract
The magnetic resonance imaging appearance of blood, as with other body tissues, is affected strongly by magnetic relaxation rates of the water protons. For blood containing only oxyhemoglobin, as for most tissues, the relaxation times are determined by diamagnetic effects related primarily to protein content. However blood containing either deoxyhemoglobin or methemoglobin exhibits additional paramagnetic relaxation effects, which have important consequences for magnetic resonance imaging of hematomas. First, the field inhomogeneity created by the concentration of paramagnetism in the red blood cells lowers the effective T2. This effect depends on field strength, and so is more striking at high fields, and is greater if gradient echoes are used. In fact, the observation of a difference in T2 with the two different echo methods provides an unequivocal indication of field inhomogeneity such as is produced by erythrocytes. A second paramagnetic relaxation effect is the direct interaction of protons with the electron spin of methemoglobin, which markedly lowers both T1 and T2. This effect is important in the imaging of hematomas that are at least several days old, after significant conversion of hemoglobin to the met form has taken place.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20178 · Cited by 685
Metadata
- Authors
- Brooks, R. A., & Di Chiro, G.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1987-11
- Volume
- 14
- Issue
- 6
- Pages
- 903-913
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2018787790
- Cited by
- 137
- References
- 0
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic resonance imaging of stationary blood: A review. https://app.cochat.ai/papers/10.1118/1.595994
- The paper
- Brooks, R. A., & Di Chiro, G. (1987). Magnetic resonance imaging of stationary blood: A review. Medical Physics. https://doi.org/10.1118/1.595994
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.