The DOI matches its Crossref record.
Radiofrequency penetration and absorption in the human body: Limitations to high‐field whole‐body nuclear magnetic resonance imaging
Abstract
This study presents experimental results about the effective depth of penetration and about the radiofrequency (rf) power absorption in humans as a function of frequency. The frequency range investigated covers 10 up to 220 MHz. For the main part, the results were derived from bench measurements of the quality factor Q, and of the resonance frequency shift due to the loading of the coil. Different types of head‐, body‐, and surface coils were investigated loaded with volunteers or metallic phantoms. For spin‐echo imaging at 2 T (85 MHz), the local specific absorption rate (SAR) was found to be ≊0.05 W/kg using a π pulse of 1‐ms duration and pulse repetition time TR =1 s. Measurements of the quality factor Q as a function of frequency show that the SAR depends upon the frequency f according to ∼f 2.15. The effective depth of rf penetration as derived drops from 17 cm at 85 MHz to 7 cm at 220 MHz. Head imaging with B1 penetrating from practically all sides into the object should be possible up to 220 MHz (5 T) with SAR values staying within the local limit of 2 W/kg as set by the FDA. Whole‐body imaging of large subjects as well as surface coil imaging is depth limited above 100‐MHz frequency. Perturbation methods are applied in order to separate the total rf power deposition in the patient into dielectric and magnetic contributions. The observed effects due to interactions of rf magnetic fields with biological tissue contradict predictions based on homogeneous tissue models. A refined tissue model with regions of high electrical conductivity, subdivided by quasi‐insulating adipose layers, provides a rationale for a better understanding of the underlying processes. At frequencies below 100 MHz, the rf power deposition in patients is apparently more evenly distributed over the exposed body volume than currently assumed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy
Krishnan, K. M. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2046907 · Cited by 819
Goodwill, P. W., & Conolly, S. M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2052284 · Cited by 395
Ardenkjær-Larsen, J. H., Laursen, I., Leunbach, I., Ehnholm, G., Wistrand, L.-G., Petersson, J. S., & Golman, K. (1998) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1438 · Cited by 381
Imaging of the active B1 field in vivo
Stollberger, R., & Wach, P. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350217 · Cited by 357
Theory and application of array coils in MR spectroscopy
Wright, S. M., & Wald, L. L. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199712)10:8<394::aid-nbm494>3.0.co;2-0 · Cited by 286
A simulation study on the resolution and sensitivity of magnetic particle imaging
Weizenecker, J., Borgert, J., & Gleich, B. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/21/001 · Cited by 267
Nanoparticles for Thermal Cancer Therapy
Day, E. S., Morton, J. G., & West, J. L. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3156800 · Cited by 263
Magnetic resonance imaging: Calculation of rates of energy absorption by a human‐torso model
Grandolfo, M., Vecchia, P., & Gandhi, O. P. (1990) · Bioelectromagnetics · doi:10.1002/bem.2250110203 · Cited by 36
Metadata
- Authors
- Röschmann, P.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1987-11
- Volume
- 14
- Issue
- 6
- Pages
- 922-931
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2168965440
- Cited by
- 232
- References
- 0
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.