The DOI matches its Crossref record.
X‐ray scatter removal by deconvolution
Abstract
The distribution of scattered x rays detected in a two‐dimensional projection radiograph at diagnostic x‐ray energies is measured as a function of field size and object thickness at a fixed x‐ray potential and air gap. An image intensifier–TV based imaging system is used for image acquisition, manipulation, and analysis. A scatter point spread function (PSF) with an assumed linear, spatially invariant response is modeled as a modified Gaussian distribution, and is characterized by two parameters describing the width of the distribution and the fraction of scattered events detected. The PSF parameters are determined from analysis of images obtained with radio‐opaque lead disks centrally placed on the source side of a homogeneous phantom. Analytical methods are used to convert the PSF into the frequency domain. Numerical inversion provides an inverse filter that operates on frequency transformed, scatter degraded images. Resultant inverse transformed images demonstrate the nonarbitrary removal of scatter, increased radiographic contrast, and improved quantitative accuracy. The use of the deconvolution method appears to be clinically applicable to a variety of digital projection images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
X‐ray scatter correction algorithm for cone beam CT imaging
Ning, R., Tang, X., & Conover, D. (2004) · Medical Physics · doi:10.1118/1.1711475 · Cited by 322
Siewerdsen, J. H., Daly, M. J., Bakhtiar, B., Moseley, D. J., Richard, S., Keller, H., & Jaffray, D. A. (2006) · Medical Physics · doi:10.1118/1.2148916 · Cited by 283
Cone‐beam volume CT breast imaging: Feasibility study
Chen, B., & Ning, R. (2002) · Medical Physics · doi:10.1118/1.1461843 · Cited by 277
Sisniega, A., Zbijewski, W., Badal, A., Kyprianou, I. S., Stayman, J. W., Vaquero, J. J., & Siewerdsen, J. H. (2013) · Medical Physics · doi:10.1118/1.4801895 · Cited by 117
Metadata
- Authors
- Seibert, J. A., & Boone, J. M.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1988-07
- Volume
- 15
- Issue
- 4
- Pages
- 567-575
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2137790413
- Cited by
- 165
- References
- 0
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: X‐ray scatter removal by deconvolution. https://app.cochat.ai/papers/10.1118/1.596208
- The paper
- Seibert, J. A., & Boone, J. M. (1988). X‐ray scatter removal by deconvolution. Medical Physics. https://doi.org/10.1118/1.596208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.