The DOI matches its Crossref record.
An unbiased signal‐to‐noise ratio measure for magnetic resonance images
Abstract
Estimating the true signal‐to‐noise ratio (SNR) of magnetic resonance (MR) images with low signal is confounded by the magnitude presentation of the data. This paper suggests a simple solution to this problem. A common method of measuring SNR compares the mean signal to the standard deviation of the noise. This SNR measure was found to be satisfactory for high but not low signal‐to‐noise image regions because of noise bias. These inconsistencies are removed by introducing unbiased definitions of the signal and noise levels in terms of their root‐mean‐square values. The approaches are compared by evaluating the SNR values for MR medical images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Signal‐to‐noise measurements in magnitude images from NMR phased arrays
Constantinides, C. D., Atalar, E., & McVeigh, E. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380524 · Cited by 510
Deistung, A., Schäfer, A., Schweser, F., Biedermann, U., Turner, R., & Reichenbach, J. R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.055 · Cited by 442
Maximum-likelihood estimation of Rician distribution parameters
Sijbers, J., den Dekker, A. J., Scheunders, P., & Van Dyck, D. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712125 · Cited by 393
Analytically exact correction scheme for signal extraction from noisy magnitude MR signals
Koay, C. G., & Basser, P. J. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.01.016 · Cited by 312
Metadata
- Authors
- McGibney, G., & Smith, M. R.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1993-07
- Volume
- 20
- Issue
- 4
- Pages
- 1077-1078
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2088780039
- Cited by
- 194
- References
- 0
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An unbiased signal‐to‐noise ratio measure for magnetic resonance images. https://app.cochat.ai/papers/10.1118/1.597004
- The paper
- McGibney, G., & Smith, M. R. (1993). An unbiased signal‐to‐noise ratio measure for magnetic resonance images. Medical Physics. https://doi.org/10.1118/1.597004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.