The DOI matches its Crossref record.
Computerized detection of clustered microcalcifications in digital mammograms using a shift‐invariant artificial neural network
Abstract
A computer‐aided diagnosis (CAD) scheme has been developed in our laboratory for the detection of clustered microcalcifications in digital mammograms. In this study, we apply a shift‐invariant neural network to eliminate false‐positive detections reported by the CAD scheme. The shift‐invariant neural network is a multilayer back‐propagation neural network with local, shift‐invariant interconnections. The advantage of the shift‐invariant neural network is that the result of the network is not dependent on the locations of the clustered microcalcifications in the input layer. The neural network is trained to detect each individual microcalcification in a given region of interest (ROI) reported by the CAD scheme. A ROI is classified as a positive ROI if the total number of microcalcifications detected in the ROI is greater than a certain number. The performance of the shift‐invariant neural network was evaluated by means of a jackknife (or holdout) method and ROC analysis using a database of 168 ROIs, as reported by the CAD scheme when applied to 34 mammograms. The analysis yielded an average area under the ROC curve (Az) of 0.91. Approximately 55% of false‐positive ROIs were eliminated without any loss of the true‐positive ROIs. The result is considerably better than that obtained in our previous study using a conventional three‐layer, feed‐forward neural network. The effect of the network structure on the performance of the shift‐invariant neural network is also studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Convolutional Neural Networks for Medical Image Analysis: Full Training or Fine Tuning?
Tajbakhsh, N., Shin, J. Y., Gurudu, S. R., Hurst, R. T., Kendall, C. B., Gotway, M. B., & Liang, J. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2535302 · Cited by 3,277
“[13], [14] and computer-aided detection of lung nodules in”
BackgroundArtificial intelligence in cancer imaging: Clinical challenges and applications
Bi, W. L., Hosny, A., Schabath, M. B., Giger, M. L., Birkbak, N. J., Mehrtash, A., Allison, T., Arnaout, O., Abbosh, C., Dunn, I. F., et al. (2019) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21552 · Cited by 1,846
Self-citationOverview of deep learning in medical imaging
Suzuki, K. (2017) · Radiological Physics and Technology · doi:10.1007/s12194-017-0406-5 · Cited by 1,087
Deep Learning in Medical Image Analysis
Chan, H.-P., Samala, R. K., Hadjiiski, L. M., & Zhou, C. (2020) · Advances in Experimental Medicine and Biology · doi:10.1007/978-3-030-33128-3_1 · Cited by 747
Deep learning in medical imaging and radiation therapy
Sahiner, B., Pezeshk, A., Hadjiiski, L. M., Wang, X., Drukker, K., Cha, K. H., Summers, R. M., & Giger, M. L. (2019) · Medical Physics · doi:10.1002/mp.13264 · Cited by 740
Self-citationGiger (2018) · doi:10.1016/j.jacr.2017.12.028 · Cited by 634
Huynh, B. Q., Li, H., & Giger, M. L. (2016) · Journal of Medical Imaging · doi:10.1117/1.jmi.3.3.034501 · Cited by 539
Self-citationSahiner, B., Chan, H.-P., Petrick, N., Wei, D., Helvie, M. A., Adler, D. D., & Goodsitt, M. M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538937 · Cited by 420
Machine Learning for Detection and Diagnosis of Disease
Sajda, P. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095802 · Cited by 409
Antropova, N., Huynh, B. Q., & Giger, M. L. (2017) · Medical Physics · doi:10.1002/mp.12453 · Cited by 389
“In the 1990s, early forms of convolutional neural networks (CNNs) were introduced for CADx by learning imaging features directly from regions of interest (ROIs) without explicit manual intervention.(2,3) Recent advances in technology have led to the widespread use of deep learning methods that use deeper and more adva…”
Computer‐aided diagnosis in the era of deep learning
Chan, H., Hadjiiski, L. M., & Samala, R. K. (2020) · Medical Physics · doi:10.1002/mp.13764 · Cited by 358
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Self-citationComputer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
El-Baz, A., Beache, G. M., Gimel'farb, G., Suzuki, K., Okada, K., Elnakib, A., Soliman, A., & Abdollahi, B. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/942353 · Cited by 277
Metadata
- Authors
- Zhang, W., Doi, K., Giger, M. L., Wu, Y., Nishikawa, R. M., & Schmidt, R. A.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1994-04
- Volume
- 21
- Issue
- 4
- Pages
- 517-524
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1973378735
- Cited by
- 168
- References
- 0
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.