Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 322

The DOI matches its Crossref record.

X‐ray imaging using amorphous selenium: Feasibility of a flat panel self‐scanned detector for digital radiology

Zhao, Wei, Rowlands, J. A. · 1995 · Medical Physics

Abstract

We investigate a concept for making a large area, flat‐panel detector for digital radiology. It employs an x‐ray sensitive photoconductor to convert incident x‐radiation to a charge image which is then electronically read out with a large area integrated circuit. The large area integrated circuit, also called an active matrix, consists of a two‐dimensional array of thin film transistors (TFTs). The potential advantages of the flat‐panel detector for digital radiography include: instantaneous digital radiographs without operator intervention; compact size approaching that of a screen‐film cassette and thus compatibility with existing x‐ray equipment; high quantum efficiency combined with high resolution. Its potential advantages over the x‐ray image intensifier (XRII)/video systems for fluoroscopy include: compactness; geometric accuracy; high resolution, and absence of veiling glare. The feasibility of the detector for digital radiology was investigated using the properties of a particular photoconductor (amorphous selenium) and active matrix array (with cadmium selenide TFTs). The results showed that it can potentially satisfy the detector design requirements for radiography (e.g., chest radiography and mammography). For fluoroscopy, the images can be obtained in real‐time but the detector is not quantum noise limited below the mean exposure rate typically used in fluoroscopy. Possible improvements in x‐ray sensitivity and noise performance for the application in fluoroscopy are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.597628

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 322

Metadata

Authors
Zhao, W., & Rowlands, J. A.
Venue
Medical Physics
Publisher
Wiley
Published
1995-10
Volume
22
Issue
10
Pages
1595-1604
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2156256714
Cited by
322
References
0
FWCI
10.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: X‐ray imaging using amorphous selenium: Feasibility of a flat panel self‐scanned detector for digital radiology. https://app.cochat.ai/papers/10.1118/1.597628
The paper
Zhao, W., & Rowlands, J. A. (1995). X‐ray imaging using amorphous selenium: Feasibility of a flat panel self‐scanned detector for digital radiology. Medical Physics. https://doi.org/10.1118/1.597628

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.