The variability of manual and computer assisted quantification of multiple sclerosis lesion volumes
The DOI matches its Crossref record.
Abstract
The high resolution and excellent soft tissue contrast of Magnetic Resonance Imaging (MRI) have enabled direct, noninvasive visualization of Multiple Sclerosis (MS) lesions in vivo. This has allowed the quantification of changes in the appearance of lesions in MR exams to be used as a measure of disease state. Nevertheless, accurate quantification techniques are subject to inter‐ and intra‐operator variability, which may hinder monitoring of disease progression. We have developed a computer program to assist an experienced operator in the quantification of MS lesions in standard spin‐echo MR exams. The accuracy of assisted and manual quantification under known conditions was studied using exams of a test phantom, while inter‐ and intra‐operator reliability and variability were studied using exams of a MS patient. Results from the phantom study show that accuracy is improved by assisted quantification. The patient exam results indicate that assisted quantification reduced inter‐operator variability from 0.34 to 0.17 cm 3, and reduced intra‐operator variability from 0.23 to 0.15 cm 3. In addition, the minimum significant change between two successive measurements of lesion volume by the same operator was 0.64 cm 3 for manual quantification and 0.42 cm 3 for assisted quantification. For two different operators making successive measurements, the minimum significant change was 0.94 cm 3 for manual quantification, but only 0.47 cm 3 for assisted quantification. Finally, the number of lesions to be monitored for an average change in volume at a given power and significance level was reduced by a factor of 2–4 by assisted quantification. These results suggest that assisted quantification may have practical applications in clinical trials, especially those that are large, multicenter, or extended over time, and therefore require lesion measurements by one or more operators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Self-citationMultiple sclerosis lesion quantification using fuzzy-connectedness principles
Udupa, J. K., Wei, L., Samarasekera, S., Miki, Y., van Buchem, M. A., & Grossman, R. I. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640750 · Cited by 314
Assessing observer variability: a user’s guide
Popović, Z. B., & Thomas, J. D. (2017) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2017.03.12 · Cited by 225
Bosc, M., Heitz, F., Armspach, J.-P., Namer, I., Gounot, D., & Rumbach, L. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00406-3 · Cited by 210
“Important total lesion load interrater variability has, for instance, been reported in Mitchell et al. (1996), and we have also observed significant disagreement between experts.”
BackgroundMethodInfluentialCook, J., Hislop, J., Adewuyi, T., Harrild, K., Altman, D., Ramsay, C., Fraser, C., Buckley, B., Fayers, P., Harvey, I., et al. (2014) · Health Technology Assessment · doi:10.3310/hta18280 · Cited by 194
Zabad, R. K., Metz, L. M., Todoruk, T. R., Zhang, Y., Mitchell, J. R., Yeung, M., Patry, D. G., Bell, R. B., & Yong, V. W. (2007) · Multiple Sclerosis Journal · doi:10.1177/1352458506070319 · Cited by 120
“Analysis was performed by a single neuroradiologist using a semi-automatic computer-assisted lesion quantification program (Segtool†) [9], which reduces the variability of MR lesion identification and volume measurement [10].”
MethodSelf-citationMitchell, J. R., Kamnitsas, K., Singleton, K. W., Whitmire, S. A., Clark-Swanson, K. R., Ranjbar, S., Rickertsen, C. R., Johnston, S. K., Egan, K. M., Rollison, D. E., et al. (2020) · Journal of Medical Imaging · doi:10.1117/1.jmi.7.5.055501 · Cited by 15
Self-citation
Metadata
- Authors
- Mitchell, J. R., Karlik, S. J., Lee, D. H., Eliasziw, M., Rice, G. P., & Fenster, A.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1996-01
- Volume
- 23
- Issue
- 1
- Pages
- 85-97
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2118601608
- Cited by
- 72
- References
- 0
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.