Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 452

The DOI matches its Crossref record.

Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography

Open access
Boone, John M., Fewell, Thomas R., Jennings, Robert J.·1997·Medical Physics

Abstract

Computer simulation is a convenient and frequently used tool in the study of x‐ray mammography, for the design of novel detector systems, the evaluation of dose deposition, x‐ray technique optimization, and other applications. An important component in the simulation process is the accurate computer‐generation of x‐ray spectra. A computer model for the generation of x‐ray spectra in the mammographic energy range from 18 kV to 40 kV has been developed. The proposed model requires no assumptions concerning the physics of x‐ray production in an x‐ray tube, but rather makes use of x‐ray spectra recently measured experimentally in the laboratories of the Center for Devices and Radiological Health. Using x‐ray spectra measured for molybdenum, rhodium, and tungsten anode x‐ray tubes at 13 different kV's (18, 20, 22,…,42 kV), a spectral model using interpolating polynomials was developed. At each energy in the spectrum, the x‐ray photon fluence was fit using 2, 3, or 4 term (depending on the energy) polynomials as a function of the applied tube voltage (kV). Using the polynomial fit coefficients determined at each 0.5 keV interval in the x‐ray spectrum, accurate x‐ray spectra can be generated for any arbitrary kV between 18 and 40 kV. Each anode material (Mo, Rh, W) uses a different set of polynomial coefficients. The molybdenum anode spectral model using interpolating polynomials is given the acronym MASMIP, and the rhodium and tungsten spectral models are called RASMIP and TASMIP, respectively. It is shown that the mean differences in photon fluence calculated over the energy channels and over the kV range from 20 to 40 kV were for MASMIP, for RASMIP, and for TASMIP. The polynomial coefficients for all three models are given in an Appendix. A short C subroutine which uses the polynomial coefficients and generates x‐ray spectra based on the proposed model is available on the World Wide Web at http://www.aip.org/epaps/epaps.html.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.598100

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 452

Metadata

Authors
Boone, J. M., Fewell, T. R., & Jennings, R. J.
Venue
Medical Physics
Publisher
Wiley
Published
1997-12
Volume
24
Issue
12
Pages
1863-1874
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2040191425
Cited by
452
References
0
FWCI
4.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. https://app.cochat.ai/papers/10.1118/1.598100
The paper
Boone, J. M., Fewell, T. R., & Jennings, R. J. (1997). Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. Medical Physics. https://doi.org/10.1118/1.598100

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.