The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
An iterative approach to the beam hardening correction in cone beam CT
Abstract
In computed tomography (CT), the beam hardening effect has been known to be one of the major sources of deterministic error that leads to inaccuracy and artifact in the reconstructed images. Because of the polychromatic nature of the x‐ray source used in CT and the energy‐dependent attenuation of most materials, Beer's law no longer holds. As a result, errors are present in the acquired line integrals or measurements of the attenuation coefficients of the scanned object. In the past, many studies have been conducted to combat image artifacts induced by beam hardening. In this paper, we present an iterative beam hardening correction approach for cone beam CT. An algorithm that utilizes a tilted parallel beam geometry is developed and subsequently employed to estimate the projection error and obtain an error estimation image, which is then subtracted from the initial reconstruction. A theoretical analysis is performed to investigate the accuracy of our methods. Phantom and animal experiments are conducted to demonstrate the effectiveness of our approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Beam hardening in X-ray reconstructive tomography
Brooks, R. A., & Chiro, G. D. (1976) · Physics in Medicine and Biology · doi:10.1088/0031-9155/21/3/004 · Cited by 606
A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners
Joseph, P. M., & Spital, R. D. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197801000-00017 · Cited by 281 · cited 1×
“To overcome these difficulties, an iterative method was proposed to estimate and correct for the projection error in the reconstructed images [4].”
MethodFeldkamp and circle-and-line cone-beam reconstruction for 3D micro-CT of vascular networks
Johnson, R. H., Hu, H., Haworth, S. T., Cho, P. S., DAWSON, C. A., & Linehan, J. H. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/020 · Cited by 54
Self-citation
Cited by
Wildenschild, D., & Sheppard, A. P. (2013) · Advances in Water Resources · doi:10.1016/j.advwatres.2012.07.018 · Cited by 1,239
Schulze, R., Heil, U., Groβ, D., Bruellmann, D., Dranischnikow, E., Schwanecke, U., & Schoemer, E. (2011) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/30642039 · Cited by 999
Vision 20/20: Single photon counting x‐ray detectors in medical imaging
Taguchi, K., & Iwanczyk, J. S. (2013) · Medical Physics · doi:10.1118/1.4820371 · Cited by 948
CT artifacts: causes and reduction techniques
Boas, F. E., & Fleischmann, D. (2012) · Imaging in Medicine · doi:10.2217/iim.12.13 · Cited by 848
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
Metadata
- Authors
- Hsieh, J., Molthen, R. C., Dawson, C. A., & Johnson, R. H.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2000-01
- Volume
- 27
- Issue
- 1
- Pages
- 23-29
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2168730277
- Cited by
- 280
- References
- 4
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An iterative approach to the beam hardening correction in cone beam CT. https://app.cochat.ai/papers/10.1118/1.598853
- The paper
- Hsieh, J., Molthen, R. C., Dawson, C. A., & Johnson, R. H. (2000). An iterative approach to the beam hardening correction in cone beam CT. Medical Physics. https://doi.org/10.1118/1.598853
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.