The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Sources of variation in profile analysis. I. Individual differences and extended training
Abstract
This study investigated two sources of variance in the ability to discriminate auditory profiles: individual differences and extended training. The goals of the study were (1) to determine the range and origins of individual differences in profile analysis and (2) to determine whether those who initially had poor sensitivity to changes in spectral shape could eventually acquire finer sensitivity. Profile stimuli had 11 components with equal-log spacing from 200–2200 Hz. Thresholds ranged from −1 to −25 dB (signal level relative to the context level) across 46 listeners. The correlation between spectral-shape discrimination thresholds after 2000 trials and pure-tone intensity-discrimination thresholds was 0.36. The range of individual differences for pure-tone intensity discrimination and spectral-shape discrimination was about the same. Two groups of listeners were given extended practice on the profile task, one group that showed low thresholds after an initial 2000 trials of practice and another that showed much higher initial thresholds. All listeners improved during the course of the first 2000 trials of training. Most of the poor listeners continued to improve during 9000 trials of training. Individual differences in the listeners’ sensitivity to changes in spectral shape still existed after the extended practice.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“their results suggest that it is not so much the exact morphology of the ear (an acoustic factor) that determines sound localization performance, but the individual's ability to detect spectral cues (a perceptual factor)”
From An investigation of matching symmetry in the human pinnae with possible implications for 3D ear recognition and sound localization (2015) · cites this paper as Drennan & Watson, 2001
Citations
Cites
Transformed Up-Down Methods in Psychoacoustics
Levitt, H. (1971) · The Journal of the Acoustical Society of America · doi:10.1121/1.1912375 · Cited by 5,591
Intensity Discrimination of Pulsed Sinusoids: The Effects of Filtered Noise
Viemeister, N. F. (1972) · The Journal of the Acoustical Society of America · doi:10.1121/1.1912970 · Cited by 110
Minimum spectral contrast for vowel identification by normal-hearing and hearing-impaired listeners
Leek, M. R., Dorman, M. F., & Summerfield, A. Q. (1987) · The Journal of the Acoustical Society of America · doi:10.1121/1.395024 · Cited by 101
Individual differences in simultaneous masking with random-frequency, multicomponent maskers
Neff, D. L., & Dethlefs, T. M. (1995) · The Journal of the Acoustical Society of America · doi:10.1121/1.413748 · Cited by 83
Spectral weights in profile listening
Berg, B. G., & Green, D. M. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399725 · Cited by 68
Successive versus simultaneous comparison in auditory intensity discrimination
Green, D. M., Kidd, G. D., & Kuffner, M. P. (1983) · The Journal of the Acoustical Society of America · doi:10.1121/1.389009 · Cited by 68
Auditory profile analysis: Frequency, phase, and Weber’s Law
Green, D. M., & Mason, C. R. (1985) · The Journal of the Acoustical Society of America · doi:10.1121/1.392179 · Cited by 53
Profile analysis: Critical bands and duration
Green, D. M., Mason, C. R., & Kidd, G. D. (1984) · The Journal of the Acoustical Society of America · doi:10.1121/1.390765 · Cited by 52
Individual differences in auditory capabilities. I.
Johnson, D. M., Watson, C. S., & Jensen, J. K. (1987) · The Journal of the Acoustical Society of America · doi:10.1121/1.394907 · Cited by 47
Self-citationSpiegel, M. F., & Green, D. M. (1982) · The Journal of the Acoustical Society of America · doi:10.1121/1.387769 · Cited by 34
Cited by
Claes, P., Reijniers, J., Shriver, M. D., Snyders, J., Suetens, P., Nielandt, J., De Tré, G., & Vandermeulen, D. (2015) · Journal of Anatomy · doi:10.1111/joa.12252 · Cited by 32
Metadata
- Authors
- Drennan, W. R., & Watson, C. S.
- Affiliations
- Department of Speech and Hearing Sciences, Indiana University, Bloomington, Indiana 47406
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2001-11-01
- Volume
- 110
- Issue
- 5
- Pages
- 2491-2497
- ISSN
- 0001-4966
- 1520-8524
- Cited by
- 15
- References
- 26
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.