Measuring vocal quality with speech synthesis
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Much previous research has demonstrated that listeners do not agree well when using traditional rating scales to measure pathological voice quality. Although these findings may indicate that listeners are inherently unable to agree in their perception of such complex auditory stimuli, another explanation implicates the particular measurement method—rating scale judgments—as the culprit. An alternative method of assessing quality—listener-mediated analysis-synthesis—was devised to assess this possibility. In this new approach, listeners explicitly compare synthetic and natural voice samples, and adjust speech synthesizer parameters to create auditory matches to voice stimuli. This method is designed to replace unstable internal standards for qualities like breathiness and roughness with externally presented stimuli, to overcome major hypothetical sources of disagreement in rating scale judgments. In a preliminary test of the reliability of this method, listeners were asked to adjust the signal-to-noise ratio for 12 synthetic pathological voices so that the resulting stimuli matched the natural target voices as well as possible For comparison to the synthesis judgments, listeners also judged the noisiness of the natural stimuli in a separate task using a traditional visual-analog rating scale. For 9 of the 12 voices, agreement among listeners was significantly (and substantially) greater for the synthesis task than for the rating scale task. Response variances for the two tasks did not differ for the remaining three voices. However, a second experiment showed that the synthesis settings that listeners selected for these three voices were within a difference limen, and therefore observed differences were perceptually insignificant. These results indicate that listeners can in fact agree in their perceptual assessments of voice quality, and that analysis-synthesis can measure perception reliably.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acoustic correlates of breathy vocal quality: dysphonic voices and continuous speech.
Hillenbrand, J., & Houde, R. A. (1996) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jshr.3902.311 · Cited by 631
Cited by
Consensus Auditory-Perceptual Evaluation of Voice: Development of a Standardized Clinical Protocol
Kempster, G. B., Gerratt, B. R., Verdolini Abbott, K., Barkmeier-Kraemer, J., & Hillman, R. E. (2009) · American Journal of Speech-Language Pathology · doi:10.1044/1058-0360(2008/08-0017 · Cited by 1,008
Self-citationScherer, K. R., Johnstone, & Klasmeyer, G. (2002) · Handbook of Affective Sciences · doi:10.1093/oso/9780195126013.003.0023 · Cited by 426
Evidence-Based Clinical Voice Assessment: A Systematic Review
Roy, N., Barkmeier-Kraemer, J., Eadie, T., Sivasankar, M. P., Mehta, D., Paul, D., & Hillman, R. (2013) · American Journal of Speech-Language Pathology · doi:10.1044/1058-0360(2012/12-0014 · Cited by 341
Establishing Validity of the Consensus Auditory-Perceptual Evaluation of Voice (CAPE-V)
Zraick, R. I., Kempster, G. B., Connor, N. P., Thibeault, S., Klaben, B. K., Bursac, Z., Thrush, C. R., & Glaze, L. E. (2011) · American Journal of Speech-Language Pathology · doi:10.1044/1058-0360(2010/09-0105 · Cited by 300
Auditory-Perceptual Evaluation of Disordered Voice Quality
Oates, J. (2009) · Folia Phoniatrica et Logopaedica · doi:10.1159/000200768 · Cited by 294
Metadata
- Authors
- Gerratt, B. R., & Kreiman, J.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2001-11-01
- Volume
- 110
- Issue
- 5
- Pages
- 2560-2566
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2160876478
- Cited by
- 99
- References
- 1
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring vocal quality with speech synthesis. https://app.cochat.ai/papers/10.1121/1.1409969
- The paper
- Gerratt, B. R., & Kreiman, J. (2001). Measuring vocal quality with speech synthesis. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.1409969
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.