Speech dynamic range and its effect on cochlear implant performance
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
This study examines optimal conversions of speech sounds to audible electric currents in cochlear-implant listeners. The speech dynamic range was measured for 20 consonants and 12 vowels spoken by five female and five male talkers. Even when the maximal root-mean-square (rms) level was normalized for all phoneme tokens, both broadband and narrow-band acoustic analyses showed an approximately 50-dB distribution of speech envelope levels. Phoneme recognition was also obtained in ten CLARION implant users as a function of the input dynamic range from 10 to 80 dB in 10-dB steps. Acoustic amplitudes within a specified input dynamic range were logarithmically mapped into the 10–20-dB range of electric stimulation typically found in cochlear-implant users. Consistent with acoustic data, the perceptual data showed that a 50–60-dB input dynamic range produced optimal speech recognition in these implant users. The present results indicate that speech dynamic range is much greater than the commonly assumed 30-dB range. A new amplitude mapping strategy, based on envelope distribution differences between consonants and vowels, is proposed to optimize acoustic-to-electric mapping of speech sounds. This new strategy will use a logarithmic map for low-frequency channels and a more compressive map for high-frequency channels, and may improve overall speech recognition for cochlear-implant users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acoustic characteristics of American English vowels
Hillenbrand, J., Getty, L. A., Clark, M. J., & Wheeler, K. (1995) · The Journal of the Acoustical Society of America · doi:10.1121/1.411872 · Cited by 2,072
Methods for the Calculation and Use of the Articulation Index
Kryter, K. D. (1962) · The Journal of the Acoustical Society of America · doi:10.1121/1.1909094 · Cited by 369
Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man
Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L. (1978) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894780870s602 · Cited by 334
Human hearing enhanced by noise11Published on the World Wide Web on 23 May 2000.
Zeng, F.-G., Fu, Q.-J., & Morse, R. (2000) · Brain Research · doi:10.1016/s0006-8993(00)02475-6 · Cited by 309
Self-citationMonosyllabic word recognition at higher-than-normal speech and noise levels
Studebaker, G. A., Sherbecoe, R. L., McDaniel, D. M., & Gwaltney, C. A. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.426848 · Cited by 227
Identification of temporal envelope cues in Chinese tone recognition
Fu, Q., & Zeng, F. (2000) · Asia Pacific Journal of Speech Language and Hearing · doi:10.1179/136132800807547582 · Cited by 166
Self-citationThe effect of parametric variations of cochlear implant processors on speech understanding
Loizou, P. C., Poroy, O., & Dorman, M. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.429612 · Cited by 164
Amplitude Mapping and Phoneme Recognition in Cochlear Implant Listeners
Zeng, F.-G., & Galvin, J. J. (1999) · Ear and Hearing · doi:10.1097/00003446-199902000-00006 · Cited by 161
Self-citationLoudness-Coding Mechanisms Inferred from Electric Stimulation of the Human Auditory System
Zeng, F., & Shannon, R. V. (1994) · Science · doi:10.1126/science.8160013 · Cited by 117
Self-citationLoudness balance between electric and acoustic stimulation
Zeng, F., & Shannon, R. V. (1992) · Hearing Research · doi:10.1016/0378-5955(92)90024-h · Cited by 85
Self-citation
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Self-citationMusic Perception with Cochlear Implants: A Review
McDermott, H. J. (2004) · Trends in Amplification · doi:10.1177/108471380400800203 · Cited by 549
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Self-citationOptogenetic stimulation of the auditory pathway
Hernandez, V. H., Gehrt, A., Reuter, K., Jing, Z., Jeschke, M., Mendoza Schulz, A., Hoch, G., Bartels, M., Vogt, G., Garnham, C. W., et al. (2014) · Journal of Clinical Investigation · doi:10.1172/jci69050 · Cited by 188
An Ultra-Low-Power Programmable Analog Bionic Ear Processor
Sarpeshkar, R., Salthouse, C., Sit, J.-J., Baker, M. W., Zhak, S. M., Lu, T. K.-T., Turicchia, L., & Balster, S. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844043 · Cited by 171
Metadata
- Authors
- Zeng, F.-G., Grant, G., Niparko, J., Galvin, J., Shannon, R., Opie, J., & Segel, P.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2002-01-01
- Volume
- 111
- Issue
- 1
- Pages
- 377-386
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W1984421695
- Cited by
- 171
- References
- 11
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.