The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The magnitude of radiation force on ultrasound contrast agents
Abstract
High-speed photography of insonified bubbles with a time resolution of 10 ns allows observations of translation due to radiation force, in addition to the visualization of radial oscillations. A modified version of the Rayleigh–Plesset equation is used to estimate the radius–time behavior of insonified microbubbles, and the accuracy of this model is verified experimentally. The translation of insonified microbubbles is calculated using a differential equation relating the acceleration of the bubble to the forces due to acoustic radiation and the drag imposed by the fluid. Simulations and experiments indicate that microbubbles translate significant distances with clinically relevant parameters. A 1.5 micron radius contrast agent can translate over 5 microns during a single 20-cycle, 2.25 MHz, 380 kPa acoustic pulse, achieving velocities over 0.5 m/s. Therefore, radiation force should be considered during an ultrasonic examination because of the possibility of influencing the position and flow velocity of the contrast agents with the interrogating acoustic beam.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Novel Site-Targeted Ultrasonic Contrast Agent With Broad Biomedical Application
Lanza, G. M., Wallace, K. D., Scott, M. J., Cacheris, W. P., Abendschein, D. R., Christy, D. H., Sharkey, A. M., Miller, J. G., Gaffney, P. J., & Wickline, S. A. (1996) · Circulation · doi:10.1161/01.cir.94.12.3334 · Cited by 406
Cited by
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Acoustic behavior of microbubbles and implications for drug delivery
Kooiman, K., Vos, H. J., Versluis, M., & de Jong, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.03.003 · Cited by 401
In vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
Ultrasound targeted CNS gene delivery for Parkinson's disease treatment
Fan, C.-H., Lin, C.-Y., Liu, H.-L., & Yeh, C.-K. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.07.004 · Cited by 97
Metadata
- Authors
- Dayton, P. A., Allen, J. S., & Ferrara, K. W.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2002-10-25
- Volume
- 112
- Issue
- 5
- Pages
- 2183-2192
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W1998476547
- Cited by
- 279
- References
- 1
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The magnitude of radiation force on ultrasound contrast agents. https://app.cochat.ai/papers/10.1121/1.1509428
- The paper
- Dayton, P. A., Allen, J. S., & Ferrara, K. W. (2002). The magnitude of radiation force on ultrasound contrast agents. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.1509428
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.