The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Understanding speech in modulated interference: Cochlear implant users and normal-hearing listeners
Abstract
Many competing noises in real environments are modulated or fluctuating in level. Listeners with normal hearing are able to take advantage of temporal gaps in fluctuating maskers. Listeners with sensorineural hearing loss show less benefit from modulated maskers. Cochlear implant users may be more adversely affected by modulated maskers because of their limited spectral resolution and by their reliance on envelope-based signal-processing strategies of implant processors. The current study evaluated cochlear implant users’ ability to understand sentences in the presence of modulated speech-shaped noise. Normal-hearing listeners served as a comparison group. Listeners repeated IEEE sentences in quiet, steady noise, and modulated noise maskers. Maskers were presented at varying signal-to-noise ratios (SNRs) at six modulation rates varying from 1 to 32 Hz. Results suggested that normal-hearing listeners obtain significant release from masking from modulated maskers, especially at 8-Hz masker modulation frequency. In contrast, cochlear implant users experience very little release from masking from modulated maskers. The data suggest, in fact, that they may show negative effects of modulated maskers at syllabic modulation rates (2–4 Hz). Similar patterns of results were obtained from implant listeners using three different devices with different speech-processor strategies. The lack of release from masking occurs in implant listeners independent of their device characteristics, and may be attributable to the nature of implant processing strategies and/or the lack of spectral detail in processed stimuli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Speech Recognition with Primarily Temporal Cues
Shannon, R. V., Zeng, F.-G., Kamath, V., Wygonski, J., & Ekelid, M. (1995) · Science · doi:10.1126/science.270.5234.303 · Cited by 3,024
Festen, J. M., & Plomp, R. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.400247 · Cited by 856
Fu, Q., Shannon, R. V., & Wang, X. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423941 · Cited by 345
Masking of speech by amplitude-modulated noise
Gustafsson, H. Å., & Arlinger, S. D. (1994) · The Journal of the Acoustical Society of America · doi:10.1121/1.408346 · Cited by 178
Cited by
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Speech recognition in noise for cochlear implant listeners: Benefits of residual acoustic hearing
Turner, C. W., Gantz, B. J., Vidal, C., Behrens, A., & Henry, B. A. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1687425 · Cited by 363
Speech and melody recognition in binaurally combined acoustic and electric hearing
Kong, Y.-Y., Stickney, G. S., & Zeng, F.-G. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1857526 · Cited by 351
Cochlear implant speech recognition with speech maskers
Stickney, G. S., Zeng, F.-G., Litovsky, R., & Assmann, P. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1772399 · Cited by 340
Sininger, Y. S., Grimes, A., & Christensen, E. (2010) · Ear & Hearing · doi:10.1097/aud.0b013e3181c8e7b6 · Cited by 258
Metadata
- Authors
- Nelson, P. B., Jin, S.-H., Carney, A. E., & Nelson, D. A.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2003-01-28
- Volume
- 113
- Issue
- 2
- Pages
- 961-968
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2070638917
- Cited by
- 318
- References
- 4
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.