The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
An approach to real-time magnetic resonance imaging for speech production
Abstract
Magnetic resonance imaging (MRI) has served as a valuable tool for studying static postures in speech production. Now, recent improvements in temporal resolution are making it possible to examine the dynamics of vocal-tract shaping during fluent speech using MRI. The present study uses spiral k-space acquisitions with a low flip-angle gradient echo pulse sequence on a conventional GE Signa 1.5-T CV/i scanner. This strategy allows for acquisition rates of 8–9 images per second and reconstruction rates of 20–24 images per second, making veridical movies of speech production now possible. Segmental durations, positions, and interarticulator timing can all be quantitatively evaluated. Data show clear real-time movements of the lips, tongue, and velum. Sample movies and data analysis strategies are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
Use of active shape models for locating structures in medical images
Cootes, T., Hill, A., Taylor, C., & Haslam, J. (1994) · Image and Vision Computing · doi:10.1016/0262-8856(94)90060-4 · Cited by 910
Fast Spiral Coronary Artery Imaging
Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280204 · Cited by 866
Electromagnetic midsagittal articulometer systems for transducing speech articulatory movements
Perkell, J. S., Cohen, M. H., Svirsky, M. A., Matthies, M. L., Garabieta, I., & Jackson, M. T. T. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.404204 · Cited by 381
A phase-based approach to the estimation of the optical flow field using spatial filtering
Gautama, T., & Van Hulle, M. A. (2002) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2002.1031944 · Cited by 335
A homogeneity correction method for magnetic resonance imaging with time-varying gradients
Noll, D. C., Meyer, C. H., Pauly, J. M., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108599 · Cited by 277
Analysis of vocal tract shape and dimensions using magnetic resonance imaging: Vowels
Baer, T., Gore, J. C., Gracco, L. C., & Nye, P. W. (1991) · The Journal of the Acoustical Society of America · doi:10.1121/1.401949 · Cited by 272
Narayanan, S. S., Alwan, A. A., & Haker, K. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.418030 · Cited by 267
Self-citationDeblurring for non‐2D fourier transform magnetic resonance imaging
Noll, D. C., Pauly, J. M., Meyer, C. H., Nishimura, D. G., & Macovskj, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250210 · Cited by 222
A three-dimensional model of tongue movement based on ultrasound and x-ray microbeam data
Stone, M. L. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399188 · Cited by 149
Acoustic modeling of American English /r/
Espy-Wilson, C., Boyce, S., Jackson, M. T. T., Narayanan, S. S., & Alwan, A. A. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.429469 · Cited by 144
Self-citationAlwan, A. A., Narayanan, S. S., & Haker, K. M. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.417972 · Cited by 108
Self-citationCross-sectional tongue shape and linguopalatal contact patterns in [s], [∫], [f], and [1]
Stone, M., Faber, A., Raphael, L. J., & Shawker, T. H. (1992) · Journal of Phonetics · doi:10.1016/s0095-4470(19)30626-6 · Cited by 107
Noise source models for fricative consonants
Narayanan, S., & Alwan, A. (2000) · IEEE Transactions on Speech and Audio Processing · doi:10.1109/89.841215 · Cited by 56
Self-citationThe Correspondence of Vocal Tract Resonance With Volumes Obtained From Magnetic Resonance Images
Moore, C. A. (1992) · Journal of Speech Language and Hearing Research · doi:10.1044/jshr.3505.1009 · Cited by 45
MRIとEPGのデータを基に流麗な近似の為の明瞭な発音のモデルへ向かって II 子音の前のrを発音
Alwan, A. A., Narayanan, S., & Haker, K. M. (1997) · The Journal of the Acoustical Society of America · Cited by 33
Self-citation
Cited by
Three-dimensional electromagnetic articulography: A measurement principle
Kaburagi, T., Wakamiya, K., & Honda, M. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1928707 · Cited by 42
Metadata
- Authors
- Narayanan, S., Nayak, K., Lee, S., Sethy, A., & Byrd, D.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2004-03-24
- Volume
- 115
- Issue
- 4
- Pages
- 1771-1776
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2032069772
- Cited by
- 313
- References
- 17
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.