The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Development of a quick speech-in-noise test for measuring signal-to-noise ratio loss in normal-hearing and hearing-impaired listeners
Abstract
This paper describes a shortened and improved version of the Speech in Noise (SIN™) Test (Etymotic Research, 1993). In the first two of four experiments, the level of a female talker relative to that of four-talker babble was adjusted sentence by sentence to produce 50% correct scores for normal-hearing subjects. In the second two experiments, those sentences-in-babble that produced either lack of equivalence or high across-subject variability in scores were discarded. These experiments produced 12 equivalent lists, each containing six sentences, with one sentence at each adjusted signal-to-noise ratio of 25, 20, 15, 10, 5, and 0 dB. Six additional lists were also made equivalent when the scores of particular pairs were averaged. The final lists comprise the “QuickSIN” test that measures the SNR a listener requires to understand 50% of key words in sentences in a background of babble. The standard deviation of single-list scores is 1.4 dB SNR for hearing-impaired subjects, based on test-retest data. A single QuickSIN list takes approximately one minute to administer and provides an estimate of SNR loss accurate to ±2.7 dB at the 95% confidence level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nilsson, M., Soli, S. D., & Sullivan, J. A. (1994) · The Journal of the Acoustical Society of America · doi:10.1121/1.408469 · Cited by 2,078
What can the pure-tone audiogram tell us about a patientʼs SNR loss?
Killion, M. C., & Niquette, P. A. (2000) · The Hearing Journal · doi:10.1097/00025572-200003000-00006 · Cited by 126
Self-citationThe Question of Phonetic Balance in Word Recognition Testing
Martin, F. N., Champlin, C. A., & Perez, D. D. (2000) · Journal of the American Academy of Audiology · doi:10.1055/s-0042-1748141 · Cited by 51
Cited by
Improving digit span assessment of short-term verbal memory
Woods, D. L., Kishiyama, M. M., Yund, E. W., Herron, T. J., Edwards, B., Poliva, O., Hink, R. F., & Reed, B. (2011) · Journal of Clinical and Experimental Neuropsychology · doi:10.1080/13803395.2010.493149 · Cited by 380
Parbery-Clark, A., Strait, D. L., Anderson, S., Hittner, E., & Kraus, N. (2011) · PLoS ONE · doi:10.1371/journal.pone.0018082 · Cited by 322
The Impact of Auditory Spectral Resolution on Listening Effort Revealed by Pupil Dilation
Winn, M. B., Edwards, J. R., & Litovsky, R. Y. (2015) · Ear & Hearing · doi:10.1097/aud.0000000000000145 · Cited by 278
Musicians experience less age-related decline in central auditory processing.
Zendel, B. R., & Alain, C. (2012) · Psychology and Aging · doi:10.1037/a0024816 · Cited by 275
Husain, F. T., Zimmerman, B., Tai, Y., Finnegan, M. K., Kay, E., Khan, F., Menard, C., & Gobin, R. L. (2019) · International Journal of Audiology · doi:10.1080/14992027.2019.1629655 · Cited by 21
Metadata
- Authors
- Killion, M. C., Niquette, P. A., Gudmundsen, G. I., Revit, L. J., & Banerjee, S.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2004-10-01
- Volume
- 116
- Issue
- 4
- Pages
- 2395-2405
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2070248369
- Cited by
- 835
- References
- 3
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a quick speech-in-noise test for measuring signal-to-noise ratio loss in normal-hearing and hearing-impaired listeners. https://app.cochat.ai/papers/10.1121/1.1784440
- The paper
- Killion, M. C., Niquette, P. A., Gudmundsen, G. I., Revit, L. J., & Banerjee, S. (2004). Development of a quick speech-in-noise test for measuring signal-to-noise ratio loss in normal-hearing and hearing-impaired listeners. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.1784440
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.