Forward-masked spatial tuning curves in cochlear implant users
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Forward-masked psychophysical spatial tuning curves (fmSTCs) were measured in twelve cochlear-implant subjects, six using bipolar stimulation (Nucleus devices) and six using monopolar stimulation (Clarion devices). fmSTCs were measured at several probe levels on a middle electrode using a fixed-level probe stimulus and variable-level maskers. The average fmSTC slopes obtained in subjects using bipolar stimulation (3.7dB∕mm) were approximately three times steeper than average slopes obtained in subjects using monopolar stimulation (1.2dB∕mm). Average spatial bandwidths were about half as wide for subjects with bipolar stimulation (2.6mm) than for subjects with monopolar stimulation (4.6mm). None of the tuning curve characteristics changed significantly with probe level. fmSTCs replotted in terms of acoustic frequency, using Greenwood’s [J. Acoust. Soc. Am. 33, 1344–1356 (1961)] frequency-to-place equation, were compared with forward-masked psychophysical tuning curves obtained previously from normal-hearing and hearing-impaired acoustic listeners. The average tuning characteristics of fmSTCs in electric hearing were similar to the broad tuning observed in normal-hearing and hearing-impaired acoustic listeners at high stimulus levels. This suggests that spatial tuning is not the primary factor limiting speech perception in many cochlear implant users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transformed Up-Down Methods in Psychoacoustics
Levitt, H. (1971) · The Journal of the Acoustical Society of America · doi:10.1121/1.1912375 · Cited by 5,477
Current steering creates additional pitch percepts in adult cochlear implant recipients
Firszt, J. B., Koch, D. B., Downing, M., & Litvak, L. (2007) · Otology & Neurotology · doi:10.1097/01.mao.0000281803.36574.bc · Cited by 150
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“Basic psychophysical performance in cochlear implants: (A) Loudness growth as a function of current level from three studies [67]; (B) Pitch estimate as a function of electric stimulation rate ( -axis) and place (symbols) [51]; (C) Spatial tuning curves in a cochlear implant user (squares superimposed with the two sha…”
BackgroundCochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation
Zhu, Z., Tang, Q., Zeng, F.-G., Guan, T., & Ye, D. (2012) · Hearing Research · doi:10.1016/j.heares.2011.11.005 · Cited by 115
“…method of choice in both acoustic and electric hearing for its ability to not only characterize the sharpness of spatial selectivity but also identify the underlying nerve survival pattern, such as dead regions (e.g., Dingemanse et al., 2006; Moore and Alcantara, 2001; Nelson et al., 2008).”
BackgroundMethodInfluentialCombined optical and electrical stimulation of neural tissue in vivo
Duke, A. R., Cayce, J. M., Malphrus, J. D., Konrad, P., Mahadevan-Jansen, A., & Jansen, E. D. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3257230 · Cited by 76
Metadata
- Authors
- Nelson, D. A., Donaldson, G. S., & Kreft, H.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2008-03-01
- Volume
- 123
- Issue
- 3
- Pages
- 1522-1543
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2065209903
- Cited by
- 97
- References
- 2
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Forward-masked spatial tuning curves in cochlear implant users. https://app.cochat.ai/papers/10.1121/1.2836786
- The paper
- Nelson, D. A., Donaldson, G. S., & Kreft, H. (2008). Forward-masked spatial tuning curves in cochlear implant users. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.2836786
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.