Material property estimation for tubes and arteries using ultrasound radiation force and analysis of propagating modes
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Arterial elasticity has been proposed as an independent predictor of cardiovascular diseases and mortality. Identification of the different propagating modes in thin shells can be used to characterize the elastic properties. Ultrasound radiation force was used to generate local mechanical waves in the wall of a urethane tube or an excised pig carotid artery. The waves were tracked using pulse-echo ultrasound. A modal analysis using two-dimensional discrete fast Fourier transform was performed on the time–space signal. This allowed the visualization of different modes of propagation and characterization of dispersion curves for both structures. The urethane tube/artery was mounted in a metallic frame, embedded in tissue-mimicking gelatin, cannulated, and pressurized over a range of 10–100 mmHg. The k-space and the dispersion curves of the urethane tube showed one mode of propagation, with no effect of transmural pressure. Fitting of a Lamb wave model estimated Young’s modulus in the urethane tube around 560 kPa. Young’s modulus of the artery ranged from 72 to 134 kPa at 10 and 100 mmHg, respectively. The changes observed in the artery dispersion curves suggest that this methodology of exciting mechanical waves and characterizing the modes of propagation has potential for studying arterial elasticity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001) · Hypertension · doi:10.1161/01.hyp.37.5.1236 · Cited by 3,856
Normal Vascular Aging: Differential Effects on Wave Reflection and Aortic Pulse Wave Velocity
McEniery, C. M., Yasmin, Hall, I. R., Qasem, A., Wilkinson, I. B., & Cockcroft, J. R. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.037 · Cited by 1,359
Clinical applications of arterial stiffness; definitions and reference values
O'Rourke, M. F., Staessen, J. A., Vlachopoulos, C., Duprez, D., & Plante, G. E. E. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02319-6 · Cited by 1,100
Aortic Stiffness Is an Independent Predictor of Fatal Stroke in Essential Hypertension
Laurent, S., Katsahian, S., Fassot, C., Tropeano, A.-I., Gautier, I., Laloux, B., & Boutouyrie, P. (2003) · Stroke · doi:10.1161/01.str.0000065428.03209.64 · Cited by 1,057
Impact of Aortic Stiffness Attenuation on Survival of Patients in End-Stage Renal Failure
Guerin, A. P., Blacher, J., Pannier, B., Marchais, S. J., Safar, M. E., & London, G. M. (2001) · Circulation · doi:10.1161/01.cir.103.7.987 · Cited by 1,040
A two-dimensional Fourier transform method for the measurement of propagating multimode signals
Alleyne, D. N., & Cawley, P. (1991) · The Journal of the Acoustical Society of America · doi:10.1121/1.400530 · Cited by 1,010
The velocity of pulse wave in man
Bramwell, J. C., & Hill, A. V. (1922) · Proceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character · doi:10.1098/rspb.1922.0022 · Cited by 806
A fundamental limit on delay estimation using partially correlated speckle signals
Walker, W. F., & Trahey, G. E. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.365243 · Cited by 479
Latham, R. D., Westerhof, N., Sipkema, P., Rubal, B. J., Reuderink, P., & Murgo, J. P. (1985) · Circulation · doi:10.1161/01.cir.72.6.1257 · Cited by 454
Dolan, E., Thijs, L., Li, Y., Atkins, N., McCormack, P., McClory, S., O’Brien, E., Staessen, J. A., & Stanton, A. V. (2006) · Hypertension · doi:10.1161/01.hyp.0000200699.74641.c5 · Cited by 394
Determination of pulse wave velocities with computerized algorithms
Chiu, Y. C., Arand, P. W., Shroff, S. G., Feldman, T., & Carroll, J. D. (1991) · American Heart Journal · doi:10.1016/0002-8703(91)90153-9 · Cited by 313
Multiaxial Mechanical Behavior of Biological Materials
Sacks, M. S., & Sun, W. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.011303.120714 · Cited by 304
Ultrasonic Nondestructive Evaluation: Engineering and Biological Material Characterization
Kundu, T. (2009) · Cited by 301
Bank, A. J., Wang, H., Holte, J. E., Mullen, K., Shammas, R., & Kubo, S. H. (1996) · Circulation · doi:10.1161/01.cir.94.12.3263 · Cited by 248
Simultaneous assessment of diameter and pressure waveforms in the carotid artery
Meinders, J. M., & Hoeks, A. P. G. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.10.014 · Cited by 238
Kanai, H. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1561662 · Cited by 213
Biomedical Applications of Radiation Force of Ultrasound: Historical Roots and Physical Basis
Sarvazyan, A. P., Rudenko, O. V., & Nyborg, W. L. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.05.015 · Cited by 210
A spline-based algorithm for continuous time-delay estimation using sampled data
Viola, F., & Walker, W. F. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1397352 · Cited by 194
Fonck, E., Prod'hom, G., Roy, S., Augsburger, L., Rüfenacht, D. A., & Stergiopulos, N. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01108.2006 · Cited by 175
The Aging of Elastic and Muscular Arteries
Cameron, J. D., Bulpitt, C. J., Pinto, E. S., & Rajkumar, C. (2003) · Diabetes Care · doi:10.2337/diacare.26.7.2133 · Cited by 161
Use of arterial transfer functions for the derivation of aortic waveform characteristics
Hope, S. A., Tay, D. B. H., Meredith, I. T., & Cameron, J. D. (2003) · Journal of Hypertension · doi:10.1097/00004872-200307000-00017 · Cited by 160
Pulse Wave Imaging for Noninvasive and Quantitative Measurement of Arterial Stiffness In Vivo
Vappou, J., Luo, J., & Konofagou, E. E. (2010) · American Journal of Hypertension · doi:10.1038/ajh.2009.272 · Cited by 159
Arterial stiffness as a risk factor for coronary atherosclerosis
Duprez, D. A., & Cohn, J. N. (2007) · Current Atherosclerosis Reports · doi:10.1007/s11883-007-0010-y · Cited by 157
Arterial Stiffness, Vascular Disease, and Risk of Cardiovascular Events
Cohn, J. N. (2006) · Circulation · doi:10.1161/circulationaha.105.600866 · Cited by 149
Pulse Pressure Predicts Cardiovascular Risk in Patients With Type 2 Diabetes Mellitus
Cockcroft, J. R., Wilkinson, I. B., EVANS, M., McEwan, P., PETERS, J., Davies, S. P., Scanlon, M. F., & Currie, C. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.05.009 · Cited by 114
Noninvasive method for estimation of complex elastic modulus of arterial vessels
Zhang, X., Kinnick, R. R., Fatemi, M., & Greenleaf, J. F. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1428047 · Cited by 109
Self-citationArterial stiffness and prediction of cardiovascular risk
Kingwell, B. A., & Gatzka, C. D. (2002) · Journal of Hypertension · doi:10.1097/00004872-200212000-00006 · Cited by 74
Contractile Responses in Arteries Subjected to Hypertensive Pressure in Seven-Day Organ Culture
Han, H., & Ku, D. N. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1376391 · Cited by 51
Cited by
Acoustic Waves in Medical Imaging and Diagnostics
Sarvazyan, A. P., Urban, M. W., & Greenleaf, J. F. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.02.006 · Cited by 223
“…2005; Klatt et al. 2007; Asbach et al. 2008; Tanter et al. 2008; Chen et al. 2009; Deffieux et al. 2009; Muller et al. 2009; Urban and Greenleaf 2009; Asbach et al. 2010; Couade et al. 2010; Gennisson et al. 2010; Amador et al. 2011; Bernal et al. 2011; Mitri et al. 2011; Nenadic et al. 2011c).”
BackgroundMethodSelf-citationSong, P., Zhao, H., Manduca, A., Urban, M. W., Greenleaf, J. F., & Chen, S. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2205586 · Cited by 217
“Shear wave dispersion analysis using 2-D Fourier transform [25] (Fig.”
MethodSelf-citationBrum, J., Bernal, M., Gennisson, J. L., & Tanter, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/3/505 · Cited by 190
“…measured in tissues due to viscosity (e.g. muscle or liver) (Deffieux et al 2009, Gennisson et al 2010, Muller et al 2009), guided wave propagation (e.g. cornea or arteries) (Tanter et al 2009, Bernal et al 2011, Couade et al 2010) or both (e.g. myocardium or bladder) (Nenadic et al 2011, 2013).”
BackgroundMethodInfluentialSelf-citationElastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
“Nonetheless, the application of wave theories has been incorporated into elastographic studies of biological structures including arteries (Bernal et al 2011, Urban et al 2015), skin layers (Kirkpatrick 2003, Urban et al 2015), tendons (Jenkyn et al 2003, Drakonaki et al 2009, Brum et al 2014,…”
Background
Metadata
- Authors
- Bernal, M., Nenadic, I., Urban, M. W., & Greenleaf, J. F.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2011-03-01
- Volume
- 129
- Issue
- 3
- Pages
- 1344-1354
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2033361527
- Cited by
- 226
- References
- 28
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.