Pulsed photoacoustic Doppler flowmetry using time-domain cross-correlation: Accuracy, resolution and scalability
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The feasibility of making spatially resolved measurements of blood velocity using a pulsed photoacoustic Doppler technique in acoustic resolution mode has been investigated. Doppler time shifts were quantified via cross-correlation of photoacoustic waveform pairs generated within a blood-simulating phantom using pairs of light pulses. The phantom comprised micron-scale absorbers imprinted on an acetate sheet and moved at known velocities. The photoacoustic waves were detected using PZT ultrasound transducers operating at center frequencies of 20 MHz, 5 MHz and 3.5 MHz; measurements of velocity and resolution were calculated from the mean cross-correlation function of 25 waveform pairs. Velocities in the range ±0.15 to ±1.5 ms−1 were quantified with accuracies as low as 1%. The transducer focal beam width determines a maximum measurable velocity |Vmax| beyond which correlation is lost due to absorbers moving out of the focal beam between the two laser pulses. Below |Vmax| a measurement resolution of <4% of the measured velocity was achieved. Resolution and |Vmax| can be scaled to much lower velocities such as those encountered in microvasculature (< 50 mms−1). The advantage of pulsed rather than continuous-wave excitation is that spatially resolved velocity measurements can be made, offering the prospect of mapping flow within the microcirculation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic Doppler Effect from Flowing Small Light-Absorbing Particles
Fang, H., Maslov, K., & Wang, L. V. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.184501 · Cited by 171
Cited by
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Self-citationYao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Review of Photoacoustic Flow Imaging: Its Current State and Its Promises
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.08.001 · Cited by 84
Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids
Brunker, J., & Beard, P. (2016) · Scientific Reports · doi:10.1038/srep20902 · Cited by 32
Self-citationZhang, R., Yao, J., Maslov, K. I., & Wang, L. V. (2013) · Applied Physics Letters · doi:10.1063/1.4819735 · Cited by 17
Metadata
- Authors
- Brunker, J., & Beard, P.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2012-09-01
- Volume
- 132
- Issue
- 3
- Pages
- 1780-1791
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2054871318
- Cited by
- 64
- References
- 1
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.