Cited by 556Sports Performance and TrainingPhysical Activity and HealthSports Dynamics and Biomechanics

The Reliability of MinimaxX Accelerometers for Measuring Physical Activity in Australian Football

Boyd, Luke J., Ball, Kevin, Aughey, Robert J.·2011·International Journal of Sports Physiology and Performance

Abstract

Purpose: To assess the reliability of triaxial accelerometers as a measure of physical activity in team sports. Methods: Eight accelerometers (MinimaxX 2.0, Catapult, Australia) were attached to a hydraulic universal testing machine (Instron 8501) and oscillated over two protocols (0.5 g and 3.0 g) to assess within- and between-device reliability. A static assessment was also conducted. Secondly, 10 players were instrumented with two accelerometers during Australian football matches. The vector magnitude was calculated, expressed as Player load and assessed for reliability using typical error ( TE) ± 90% confidence intervals ( CI), and expressed as a coefficient of variation ( CV%). The smallest worthwhile difference ( SWD) in Player load was calculated to determine if the device was capable of detecting differences in physical activity. Results: Laboratory: Within- (Dynamic: CV 0.91 to 1.05%; Static: CV 1.01%) and between-device (Dynamic: CV 1.02 to 1.04%; Static: CV 1.10%) reliability was acceptable across each test. Field: The between-device reliability of accelerometers during Australian football matches was also acceptable ( CV 1.9%). The SWD was 5.88%. Conclusions: The reliability of the MinimaxX accelerometer is acceptable both within and between devices under controlled laboratory conditions, and between devices during field testing. MinimaxX accelerometers can be confidently utilized as a reliable tool to measure physical activity in team sports across multiple players and repeated bouts of activity. The noise ( CV%) of Player load was lower than the signal ( SWD), suggesting that accelerometers can detect changes or differences in physical activity during Australian football.

Integrity signals

Registry

Crossref · 10.1123/ijspp.6.3.311

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Boyd, L. J., Ball, K., & Aughey, R. J.
Affiliations
Victoria University (AU)
Venue
International Journal of Sports Physiology and Performance
Published
2011-09
Volume
6
Issue
3
Pages
311-321
ISSN
  • 1555-0265 (ISSN-L)
  • 1555-0273
OpenAlex
W2151724600
Cited by
556
References
1
Citations by year
2026: 19 · 2025: 30 · 2024: 21 · 2023: 34 · 2022: 45 · 2021: 51 · 2020: 59 · 2019: 59 · 2018: 58 · 2017: 47 · 2016: 36 · 2015: 25 · 2014: 31 · 2013: 23 · 2012: 12
FWCI
23.85
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Sports Physiology and Performance (publishedVersion)
  • PubMed (publishedVersion)
  • Victoria University Research Repository (Victoria University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
  • Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
Keywords
triaxial accelerometer, physical activity measurement, Australian football, team sports, measurement reliability, player load, accelerometer noise
MeSH terms
Adult, Australia, Biomechanical Phenomena, Equipment Design, Football, Humans, Male, Materials Testing, Miniaturization, Motor Activity, Task Performance and Analysis, Reproducibility of Results, Athletic Performance, Young Adult, Actigraphy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review